?? form1.frm
字號:
VERSION 5.00
Object = "{248DD890-BB45-11CF-9ABC-0080C7E7B78D}#1.0#0"; "MSWINSCK.OCX"
Begin VB.Form Form1
Caption = "Form1"
ClientHeight = 4875
ClientLeft = 60
ClientTop = 345
ClientWidth = 6435
LinkTopic = "Form1"
ScaleHeight = 4875
ScaleWidth = 6435
StartUpPosition = 3 'Windows Default
Begin MSWinsockLib.Winsock Winsock1
Left = 6000
Top = 960
_ExtentX = 741
_ExtentY = 741
_Version = 393216
End
Begin VB.Frame Frame1
Caption = "數據接收區"
Height = 3255
Left = 120
TabIndex = 8
Top = 1440
Width = 6135
Begin VB.TextBox Text4
Height = 2775
Left = 120
MultiLine = -1 'True
ScrollBars = 2 'Vertical
TabIndex = 9
Top = 360
Width = 5895
End
End
Begin VB.CommandButton Command2
Caption = "發送"
Height = 375
Left = 4560
TabIndex = 7
Top = 840
Width = 1335
End
Begin VB.TextBox Text3
Height = 350
Left = 1200
TabIndex = 6
Text = "1234567890abcdefghijk"
Top = 840
Width = 3015
End
Begin VB.CommandButton Command1
Caption = "連接"
Height = 375
Left = 4560
TabIndex = 4
Top = 240
Width = 1335
End
Begin VB.TextBox Text2
Height = 350
Left = 3240
TabIndex = 3
Text = "4001"
Top = 240
Width = 975
End
Begin VB.TextBox Text1
Height = 350
Left = 960
TabIndex = 1
Text = "192.168.0.178"
Top = 240
Width = 1455
End
Begin VB.Label Label3
Caption = "發送數據:"
Height = 255
Left = 240
TabIndex = 5
Top = 960
Width = 975
End
Begin VB.Label Label2
Caption = "端口:"
Height = 255
Left = 2640
TabIndex = 2
Top = 360
Width = 615
End
Begin VB.Label Label1
Caption = "設備IP:"
Height = 255
Left = 240
TabIndex = 0
Top = 360
Width = 735
End
End
Attribute VB_Name = "Form1"
Attribute VB_GlobalNameSpace = False
Attribute VB_Creatable = False
Attribute VB_PredeclaredId = True
Attribute VB_Exposed = False
Dim g_Connect As Byte
Private Sub SetConnectButton()
Select Case g_Connect
Case 0 '連接已斷開
Command1.Enabled = True
Command1.Caption = "連接"
Case 1 '連接成功
Command1.Enabled = True
Command1.Caption = "斷開"
Case 2 '正在連接
Command1.Enabled = False
Command1.Caption = "連接"
End Select
End Sub
Private Sub Command1_Click()
If g_Connect = 0 Then
g_Connect = 2
Winsock1.RemoteHost = Text1.Text
Winsock1.RemotePort = Text2.Text
Winsock1.Connect
Else
g_Connect = 0
Winsock1.Close
End If
SetConnectButton
End Sub
Private Sub Command2_Click()
Winsock1.SendData Text3.Text '發送數據
End Sub
Private Sub Form_Load()
g_Connect = 0
End Sub
Private Sub Form_Unload(Cancel As Integer)
If g_Connect <> 0 Then
Winsock1.Close
End If
End Sub
Private Sub Winsock1_Close()
g_Connect = 0
Winsock1.Close
SetConnectButton
End Sub
Private Sub Winsock1_Connect()
g_Connect = 1
SetConnectButton
End Sub
Private Sub Winsock1_DataArrival(ByVal bytesTotal As Long)
Dim strData As String
Winsock1.GetData strData, vbString
Text4.Text = Text4.Text & strData
End Sub
Private Sub Winsock1_Error(ByVal Number As Integer, Description As String, ByVal Scode As Long, ByVal Source As String, ByVal HelpFile As String, ByVal HelpContext As Long, CancelDisplay As Boolean)
g_Connect = 0
Winsock1.Close
SetConnectButton
End Sub
?? 快捷鍵說明
復制代碼
Ctrl + C
搜索代碼
Ctrl + F
全屏模式
F11
切換主題
Ctrl + Shift + D
顯示快捷鍵
?
增大字號
Ctrl + =
減小字號
Ctrl + -