?? alarmint.lis
字號:
0638 .dbline 211
0638 ; pannel_led[11].ID=0;
0638 2092A101 sts _pannel_led+220+1,R2
063C .dbline 212
063C ; pannel_led[11].channel=3;
063C 83E0 ldi R24,3
063E 8093A201 sts _pannel_led+220+2,R24
0642 .dbline 213
0642 ; pannel_led[11].alarm_type=above;
0642 8AE5 ldi R24,90
0644 8093A301 sts _pannel_led+220+3,R24
0648 .dbline 214
0648 ; pannel_led[11].limit=4400;
0648 80E3 ldi R24,4400
064A 91E1 ldi R25,17
064C 9093A501 sts _pannel_led+220+4+1,R25
0650 8093A401 sts _pannel_led+220+4,R24
0654 .dbline 215
0654 ; pannel_led[11].zone=100;
0654 84E6 ldi R24,100
0656 90E0 ldi R25,0
0658 9093A701 sts _pannel_led+220+6+1,R25
065C 8093A601 sts _pannel_led+220+6,R24
0660 .dbline 216
0660 ; pannel_led[11].fullscal=4800;
0660 80EC ldi R24,4800
0662 92E1 ldi R25,18
0664 9093A901 sts _pannel_led+220+8+1,R25
0668 8093A801 sts _pannel_led+220+8,R24
066C .dbline 217
066C ; pannel_led[11].gain=10;
066C 8AE0 ldi R24,10
066E 8093AA01 sts _pannel_led+220+10,R24
0672 .dbline 218
0672 ; pannel_led[11].data=0;
0672 3092AC01 sts _pannel_led+220+11+1,R3
0676 2092AB01 sts _pannel_led+220+11,R2
067A .dbline 219
067A ; pannel_led[11].state=normal;
067A 2092AD01 sts _pannel_led+220+13,R2
067E .dbline 220
067E ; pannel_led[11].current_state=normal;
067E 2092AE01 sts _pannel_led+220+14,R2
0682 .dbline 221
0682 ; pannel_led[11].last_state=normal;
0682 2092AF01 sts _pannel_led+220+15,R2
0686 .dbline 222
0686 ; pannel_led[11].cut_off=off;
0686 85EA ldi R24,165
0688 8093B001 sts _pannel_led+220+16,R24
068C .dbline 223
068C ; pannel_led[11].displaydata=0;
068C 3092B301 sts _pannel_led+220+18+1,R3
0690 2092B201 sts _pannel_led+220+18,R2
0694 .dbline 224
0694 ; pannel_led[11].soundoff = normal;
0694 2092B101 sts _pannel_led+220+17,R2
0698 .dbline 226
0698 ;
0698 ; pannel_led[12].sen_typed=ma;
0698 2092B401 sts _pannel_led+240,R2
069C .dbline 227
069C ; pannel_led[12].ID=0;
069C 2092B501 sts _pannel_led+240+1,R2
06A0 .dbline 228
06A0 ; pannel_led[12].channel=0;
06A0 2092B601 sts _pannel_led+240+2,R2
06A4 .dbline 229
06A4 ; pannel_led[12].alarm_type=above;
06A4 8AE5 ldi R24,90
06A6 8093B701 sts _pannel_led+240+3,R24
06AA .dbline 230
06AA ; pannel_led[12].limit=550;
06AA 86E2 ldi R24,550
06AC 92E0 ldi R25,2
06AE 9093B901 sts _pannel_led+240+4+1,R25
06B2 8093B801 sts _pannel_led+240+4,R24
06B6 .dbline 231
06B6 ; pannel_led[12].zone=10;
06B6 8AE0 ldi R24,10
06B8 90E0 ldi R25,0
06BA 9093BB01 sts _pannel_led+240+6+1,R25
06BE 8093BA01 sts _pannel_led+240+6,R24
06C2 .dbline 232
06C2 ; pannel_led[12].fullscal=600;
06C2 88E5 ldi R24,600
06C4 92E0 ldi R25,2
06C6 9093BD01 sts _pannel_led+240+8+1,R25
06CA 8093BC01 sts _pannel_led+240+8,R24
06CE .dbline 233
06CE ; pannel_led[12].gain=10;
06CE 8AE0 ldi R24,10
06D0 8093BE01 sts _pannel_led+240+10,R24
06D4 .dbline 234
06D4 ; pannel_led[12].data=0;
06D4 3092C001 sts _pannel_led+240+11+1,R3
06D8 2092BF01 sts _pannel_led+240+11,R2
06DC .dbline 235
06DC ; pannel_led[12].state=normal;
06DC 2092C101 sts _pannel_led+240+13,R2
06E0 .dbline 236
06E0 ; pannel_led[12].current_state=normal;
06E0 2092C201 sts _pannel_led+240+14,R2
06E4 .dbline 237
06E4 ; pannel_led[12].last_state=normal;
06E4 2092C301 sts _pannel_led+240+15,R2
06E8 .dbline 238
06E8 ; pannel_led[12].cut_off=off;
06E8 85EA ldi R24,165
06EA 8093C401 sts _pannel_led+240+16,R24
06EE .dbline 239
06EE ; pannel_led[12].displaydata=0;
06EE 3092C701 sts _pannel_led+240+18+1,R3
06F2 2092C601 sts _pannel_led+240+18,R2
06F6 .dbline 240
06F6 ; pannel_led[12].soundoff = normal;
06F6 2092C501 sts _pannel_led+240+17,R2
06FA .dbline 242
06FA ;
06FA ; pannel_led[13].sen_typed=ma;
06FA 2092C801 sts _pannel_led+260,R2
06FE .dbline 243
06FE ; pannel_led[13].ID=0;
06FE 2092C901 sts _pannel_led+260+1,R2
0702 .dbline 244
0702 ; pannel_led[13].channel=1;
0702 81E0 ldi R24,1
0704 8093CA01 sts _pannel_led+260+2,R24
0708 .dbline 245
0708 ; pannel_led[13].alarm_type=above;
0708 8AE5 ldi R24,90
070A 8093CB01 sts _pannel_led+260+3,R24
070E .dbline 246
070E ; pannel_led[13].limit=4200;
070E 88E6 ldi R24,4200
0710 90E1 ldi R25,16
0712 9093CD01 sts _pannel_led+260+4+1,R25
0716 8093CC01 sts _pannel_led+260+4,R24
071A .dbline 247
071A ; pannel_led[13].zone=100;
071A 84E6 ldi R24,100
071C 90E0 ldi R25,0
071E 9093CF01 sts _pannel_led+260+6+1,R25
0722 8093CE01 sts _pannel_led+260+6,R24
0726 .dbline 248
0726 ; pannel_led[13].fullscal=4800;
0726 80EC ldi R24,4800
0728 92E1 ldi R25,18
072A 9093D101 sts _pannel_led+260+8+1,R25
072E 8093D001 sts _pannel_led+260+8,R24
0732 .dbline 249
0732 ; pannel_led[13].gain=10;
0732 8AE0 ldi R24,10
0734 8093D201 sts _pannel_led+260+10,R24
0738 .dbline 250
0738 ; pannel_led[13].data=0;
0738 3092D401 sts _pannel_led+260+11+1,R3
073C 2092D301 sts _pannel_led+260+11,R2
0740 .dbline 251
0740 ; pannel_led[13].state=normal;
0740 2092D501 sts _pannel_led+260+13,R2
0744 .dbline 252
0744 ; pannel_led[13].current_state=normal;
0744 2092D601 sts _pannel_led+260+14,R2
0748 .dbline 253
0748 ; pannel_led[13].last_state=normal;
0748 2092D701 sts _pannel_led+260+15,R2
074C .dbline 254
074C ; pannel_led[13].cut_off=off;
074C 85EA ldi R24,165
074E 8093D801 sts _pannel_led+260+16,R24
0752 .dbline 255
0752 ; pannel_led[13].displaydata=0;
0752 3092DB01 sts _pannel_led+260+18+1,R3
0756 2092DA01 sts _pannel_led+260+18,R2
075A .dbline 256
075A ; pannel_led[13].soundoff = normal;
075A 2092D901 sts _pannel_led+260+17,R2
075E .dbline 258
075E ;
075E ; pannel_led[14].sen_typed=ma;
075E 2092DC01 sts _pannel_led+280,R2
0762 .dbline 259
0762 ; pannel_led[14].ID=0;
0762 2092DD01 sts _pannel_led+280+1,R2
0766 .dbline 260
0766 ; pannel_led[14].channel=2;
0766 82E0 ldi R24,2
0768 8093DE01 sts _pannel_led+280+2,R24
076C .dbline 261
076C ; pannel_led[14].alarm_type=above;
076C 8AE5 ldi R24,90
076E 8093DF01 sts _pannel_led+280+3,R24
0772 .dbline 262
0772 ; pannel_led[14].limit=8000;
0772 80E4 ldi R24,8000
0774 9FE1 ldi R25,31
0776 9093E101 sts _pannel_led+280+4+1,R25
077A 8093E001 sts _pannel_led+280+4,R24
077E .dbline 263
077E ; pannel_led[14].zone=500;
077E 84EF ldi R24,500
0780 91E0 ldi R25,1
0782 9093E301 sts _pannel_led+280+6+1,R25
0786 8093E201 sts _pannel_led+280+6,R24
078A .dbline 264
078A ; pannel_led[14].fullscal=9000;
078A 88E2 ldi R24,9000
078C 93E2 ldi R25,35
078E 9093E501 sts _pannel_led+280+8+1,R25
0792 8093E401 sts _pannel_led+280+8,R24
0796 .dbline 265
0796 ; pannel_led[14].gain=10;
0796 8AE0 ldi R24,10
0798 8093E601 sts _pannel_led+280+10,R24
079C .dbline 266
079C ; pannel_led[14].data=0;
079C 3092E801 sts _pannel_led+280+11+1,R3
07A0 2092E701 sts _pannel_led+280+11,R2
07A4 .dbline 267
07A4 ; pannel_led[14].state=normal;
07A4 2092E901 sts _pannel_led+280+13,R2
07A8 .dbline 268
07A8 ; pannel_led[14].current_state=normal;
07A8 2092EA01 sts _pannel_led+280+14,R2
07AC .dbline 269
07AC ; pannel_led[14].last_state=normal;
07AC 2092EB01 sts _pannel_led+280+15,R2
07B0 .dbline 270
07B0 ; pannel_led[14].cut_off=off;
07B0 85EA ldi R24,165
07B2 8093EC01 sts _pannel_led+280+16,R24
07B6 .dbline 271
07B6 ; pannel_led[14].displaydata=0;
07B6 3092EF01 sts _pannel_led+280+18+1,R3
07BA 2092EE01 sts _pannel_led+280+18,R2
07BE .dbline 272
07BE ; pannel_led[14].soundoff = normal;
07BE 2092ED01 sts _pannel_led+280+17,R2
07C2 .dbline 274
07C2 ;
07C2 ; pannel_led[15].sen_typed=ma;
07C2 2092F001 sts _pannel_led+300,R2
07C6 .dbline 275
07C6 ; pannel_led[15].ID=0;
07C6 2092F101 sts _pannel_led+300+1,R2
07CA .dbline 276
07CA ; pannel_led[15].channel=3;
07CA 83E0 ldi R24,3
07CC 8093F201 sts _pannel_led+300+2,R24
07D0 .dbline 277
07D0 ; pannel_led[15].alarm_type=above;
07D0 8AE5 ldi R24,90
07D2 8093F301 sts _pannel_led+300+3,R24
07D6 .dbline 278
07D6 ; pannel_led[15].limit=4400;
07D6 80E3 ldi R24,4400
07D8 91E1 ldi R25,17
07DA 9093F501 sts _pannel_led+300+4+1,R25
07DE 8093F401 sts _pannel_led+300+4,R24
07E2 .dbline 279
07E2 ; pannel_led[15].zone=100;
07E2 84E6 ldi R24,100
07E4 90E0 ldi R25,0
07E6 9093F701 sts _pannel_led+300+6+1,R25
07EA 8093F601 sts _pannel_led+300+6,R24
07EE .dbline 280
07EE ; pannel_led[15].fullscal=4800;
07EE 80EC ldi R24,4800
07F0 92E1 ldi R25,18
07F2 9093F901 sts _pannel_led+300+8+1,R25
07F6 8093F801 sts _pannel_led+300+8,R24
07FA .dbline 281
07FA ; pannel_led[15].gain=10;
07FA 8AE0 ldi R24,10
07FC 8093FA01 sts _pannel_led+300+10,R24
0800 .dbline 282
0800 ; pannel_led[15].data=0;
0800 3092FC01 sts _pannel_led+300+11+1,R3
0804 2092FB01 sts _pannel_led+300+11,R2
0808 .dbline 283
0808 ; pannel_led[15].state=normal;
0808 2092FD01 sts _pannel_led+300+13,R2
080C .dbline 284
080C ; pannel_led[15].current_state=normal;
080C 2092FE01 sts _pannel_led+300+14,R2
0810 .dbline 285
0810 ; pannel_led[15].last_state=normal;
0810 2092FF01 sts _pannel_led+300+15,R2
0814 .dbline 286
0814 ; pannel_led[15].cut_off=off;
0814 85EA ldi R24,165
0816 80930002 sts _pannel_led+300+16,R24
081A .dbline 287
081A ; pannel_led[15].displaydata=0;
081A 30920302 sts _pannel_led+300+18+1,R3
081E 20920202 sts _pannel_led+300+18,R2
0822 .dbline 288
0822 ; pannel_led[15].soundoff = normal;
0822 20920102 sts _pannel_led+300+17,R2
0826 .dbline 290
0826 ;