?? da02040a.gsd
字號(hào):
Prm_Text_Ref=2
EndExtUserPrmData
ExtUserPrmData=9 "PNU in P915/7"
Unsigned16 0 0-3500
Prm_Text_Ref=2
EndExtUserPrmData
ExtUserPrmData=10 "PNU in P915/8"
Unsigned16 0 0-3500
Prm_Text_Ref=2
EndExtUserPrmData
ExtUserPrmData=11 "PNU in P915/9"
Unsigned16 0 0-3500
Prm_Text_Ref=2
EndExtUserPrmData
ExtUserPrmData=12 "PNU in P916/0"
Unsigned16 1603 1603-1603
Prm_Text_Ref=3
EndExtUserPrmData
ExtUserPrmData=13 "PNU in P916/1"
Unsigned16 1605 1605-1617
Prm_Text_Ref=3
EndExtUserPrmData
ExtUserPrmData=14 "PNU in P916/2"
Unsigned16 0 0-3500
Prm_Text_Ref=3
EndExtUserPrmData
ExtUserPrmData=15 "PNU in P916/3"
Unsigned16 0 0-3500
Prm_Text_Ref=3
EndExtUserPrmData
ExtUserPrmData=16 "PNU in P916/4"
Unsigned16 0 0-3500
Prm_Text_Ref=3
EndExtUserPrmData
ExtUserPrmData=17 "PNU in P916/5"
Unsigned16 0 0-3500
Prm_Text_Ref=3
EndExtUserPrmData
ExtUserPrmData=18 "PNU in P916/6"
Unsigned16 0 0-3500
Prm_Text_Ref=3
EndExtUserPrmData
ExtUserPrmData=19 "PNU in P916/7"
Unsigned16 0 0-3500
Prm_Text_Ref=3
EndExtUserPrmData
ExtUserPrmData=20 "PNU in P916/8"
Unsigned16 0 0-3500
Prm_Text_Ref=3
EndExtUserPrmData
ExtUserPrmData=21 "PNU in P916/9"
Unsigned16 0 0-3500
Prm_Text_Ref=3
EndExtUserPrmData
Max_User_Prm_Data_Len = 44 ;
Ext_User_Prm_Data_Const(0) = 0x0,0x0,0x0;
Ext_User_Prm_Data_Ref(3)=1
Ext_User_Prm_Data_Ref(4)=2
Ext_User_Prm_Data_Ref(6)=3
Ext_User_Prm_Data_Ref(8)=4
Ext_User_Prm_Data_Ref(10)=5
Ext_User_Prm_Data_Ref(12)=6
Ext_User_Prm_Data_Ref(14)=7
Ext_User_Prm_Data_Ref(16)=8
Ext_User_Prm_Data_Ref(18)=9
Ext_User_Prm_Data_Ref(20)=10
Ext_User_Prm_Data_Ref(22)=11
Ext_User_Prm_Data_Ref(24)=12
Ext_User_Prm_Data_Ref(26)=13
Ext_User_Prm_Data_Ref(28)=14
Ext_User_Prm_Data_Ref(30)=15
Ext_User_Prm_Data_Ref(32)=16
Ext_User_Prm_Data_Ref(34)=17
Ext_User_Prm_Data_Ref(36)=18
Ext_User_Prm_Data_Ref(38)=19
Ext_User_Prm_Data_Ref(40)=20
Ext_User_Prm_Data_Ref(42)=21
;
; Unit Diagnosis:
;
Unit_Diag_Bit(0) = "Info text for FC300";
Unit_Diag_Bit(1) = "Overflow SPM-FIFO";
Unit_Diag_Bit(2) = "Actual value is not updated";
Unit_Diag_Bit(3) = "Not used";
Unit_Diag_Bit(4) = "Not used";
Unit_Diag_Bit(5) = "Not used";
Unit_Diag_Bit(6) = "Not used";
Unit_Diag_Bit(7) = "See Manual for more information";
;
; Unit Diagnosis: Alarm word par. 16-06. Only FC 300.
;
Unit_Diag_Bit(48) = "[A] Not used"
Unit_Diag_Bit(49) = "[A] Drive overtemp."
Unit_Diag_Bit(50) = "[A] Earth fault"
Unit_Diag_Bit(51) = "[A] Not used"
Unit_Diag_Bit(52) = "[A] Controlword timeout"
Unit_Diag_Bit(53) = "[A] Over current"
Unit_Diag_Bit(54) = "[A] Torque Limit"
Unit_Diag_Bit(55) = "[A] Motor thermistor overtemp."
Unit_Diag_Bit(40) = "[A] Motor ETR overtemp."
Unit_Diag_Bit(41) = "[A] Inverter overloaded"
Unit_Diag_Bit(42) = "[A] DC link undervoltage"
Unit_Diag_Bit(43) = "[A] DC link overvoltage"
Unit_Diag_Bit(44) = "[A] Short circuit"
Unit_Diag_Bit(45) = "[A] Inrush fault"
Unit_Diag_Bit(46) = "[A] Mains phase loss"
Unit_Diag_Bit(47) = "[A] AMA not OK"
Unit_Diag_Bit(32) = "[A] Live zero error"
Unit_Diag_Bit(33) = "[A] Internal fault"
Unit_Diag_Bit(34) = "[A] Brake resistor power limit"
Unit_Diag_Bit(35) = "[A] Motor phase U is missing"
Unit_Diag_Bit(36) = "[A] Motor phase V is missing"
Unit_Diag_Bit(37) = "[A] Motor phase W is missing"
Unit_Diag_Bit(38) = "[A] Fieldbus comm. fault"
Unit_Diag_Bit(39) = "[A] 24V supply fault"
Unit_Diag_Bit(24) = "[A] Mains faliure"
Unit_Diag_Bit(25) = "[A] 1,8V supply fault"
Unit_Diag_Bit(26) = "[A] Brake resistor short circuit"
Unit_Diag_Bit(27) = "[A] Brake chopper fault"
Unit_Diag_Bit(28) = "[A] Unused"
Unit_Diag_Bit(29) = "[A] Unused"
Unit_Diag_Bit(30) = "[A] Unused"
Unit_Diag_Bit(31) = "[A] Unused"
;
; Unit Diagnosis: Warning word par. 16-07. Only FC 300.
;
Unit_Diag_Bit(112) = "[W] Not used"
Unit_Diag_Bit(113) = "[W] Drive overtemp."
Unit_Diag_Bit(114) = "[W] Earth fault"
Unit_Diag_Bit(115) = "[W] Not used"
Unit_Diag_Bit(116) = "[W] Controlword timeout"
Unit_Diag_Bit(117) = "[W] Over current"
Unit_Diag_Bit(118) = "[W] Torque limit"
Unit_Diag_Bit(119) = "[W] Motor thermistor overtemp."
Unit_Diag_Bit(104) = "[W] Motor ERT over temp."
Unit_Diag_Bit(105) = "[W] Inverter overloaded"
Unit_Diag_Bit(106) = "[W] DC link undervoltage"
Unit_Diag_Bit(107) = "[W] DC link overvoltage"
Unit_Diag_Bit(108) = "[W] DC link voltage low"
Unit_Diag_Bit(109) = "[W] DC link voltage high"
Unit_Diag_Bit(110) = "[W] Manins phase loss"
Unit_Diag_Bit(111) = "[W] No motor"
Unit_Diag_Bit(96) = "[W] Live zero error"
Unit_Diag_Bit(97) = "[W] 10V low"
Unit_Diag_Bit(98) = "[W] Brake resistor power limit"
Unit_Diag_Bit(99) = "[W] Brake resistor short circuit"
Unit_Diag_Bit(100) = "[W] Brake chopper fault"
Unit_Diag_Bit(101) = "[W] Speed limit"
Unit_Diag_Bit(102) = "[W] Fieldbus comm. fault"
Unit_Diag_Bit(103) = "[W] 24V supply fault"
Unit_Diag_Bit(88) = "[W] Mains faliure"
Unit_Diag_Bit(89) = "[W] Current limit"
Unit_Diag_Bit(90) = "[W] Not used"
Unit_Diag_Bit(91) = "[W] Not used"
Unit_Diag_Bit(92) = "[W] Not used"
Unit_Diag_Bit(93) = "[W] Not used"
Unit_Diag_Bit(94) = "[W] Not used"
Unit_Diag_Bit(95) = "[W] Warning word 2"
;
; Unit Diagnosis: Communication option warning word par. 9-53. Only FC 300.
;
Unit_Diag_Bit(160) = "[W] Conn. with Dp-master not OK"
Unit_Diag_Bit(161) = "[W] Timeout action active"
Unit_Diag_Bit(162) = "[W] FDL is not OK"
Unit_Diag_Bit(163) = "[W] Clear data command received"
Unit_Diag_Bit(164) = "[W] Actual value is not updated"
Unit_Diag_Bit(165) = "[W] Baudrate search"
Unit_Diag_Bit(166) = "[W] ASIC is not transmiting"
Unit_Diag_Bit(167) = "[W] Init of PROFIBUS is not OK"
Unit_Diag_Bit(152) = "[W] Drive is tripped"
Unit_Diag_Bit(153) = "[W] Internal CAN error"
Unit_Diag_Bit(154) = "[W] Wrong config. data from PLC"
Unit_Diag_Bit(155) = "[W] Wrong ID sent by PLC"
Unit_Diag_Bit(156) = "[W] Internal error occurred"
Unit_Diag_Bit(157) = "[W] Not configured"
Unit_Diag_Bit(158) = "[W] Clear command received"
Unit_Diag_Bit(159) = "[W] Warning 34 active"
;
;Modules
;
Module = "Profidrive standard telegram 1" 0xC3, 0xC1, 0xC1, 0xFD, 0x00, 0x01;
0
EndModule;
Module = "PPO Type 1 Module consistent PCD" 0xF3, 0xF1;
1
EndModule;
Module = "PPO Type 1 Word consistent PCD " 0xF3, 0x71;
2
EndModule;
Module = "PPO Type 2 Module consistent PCD" 0xF3, 0xF5;
3
EndModule;
Module = "PPO Type 2 Word consistent PCD " 0xF3, 0x75;
4
EndModule;
Module = "PPO Type 3 Module consistent PCD" 0xF1;
5
EndModule;
Module = "PPO Type 3 Word consistent PCD " 0x71;
6
EndModule;
Module = "PPO Type 4 Module consistent PCD" 0xF5;
7
EndModule;
Module = "PPO Type 4 Word consistent PCD " 0x75;
8
EndModule;
Module = "PPO Type 5 Module consistent PCD" 0xF3, 0xF9;
9
EndModule;
Module = "PPO Type 5 Word consistent PCD " 0xF3, 0x79;
10
EndModule;
Module = "PPO Type 6 Module consistent PCD" 0xF3;
11
EndModule;
Module = "PPO Type 6 Word consistent PCD " 0x73;
12
EndModule;
Module = "PPO Type 7 Module consistent PCD" 0xF7;
13
EndModule;
Module = "PPO Type 7 Word consistent PCD " 0x77;
14
EndModule;
Module = "PPO Type 8 Module consistent PCD" 0xF9;
15
EndModule;
Module = "PPO Type 8 Word consistent PCD " 0x79;
16
EndModule;
?? 快捷鍵說(shuō)明
復(fù)制代碼
Ctrl + C
搜索代碼
Ctrl + F
全屏模式
F11
切換主題
Ctrl + Shift + D
顯示快捷鍵
?
增大字號(hào)
Ctrl + =
減小字號(hào)
Ctrl + -