;* GSD-File for: Danfoss Drives A/S *
;* FCD 300 Series 3 Mb DPV1 *
;* *
;* File name: da030406 *
;* *
;* Contact: Danfoss Drives A/S *
;* DK 6300 Graasten *
;* Denmark *
;* Hotline: Int. + 45 74 88 61 00 *
;* E-mail: Drives_Hotline@danfoss.com *
;* *
;* Revision: da020406 Rev. 2.10 DPV0 file *
;* da030406 Rev. 3.00 DPV1 file *
;* da030406 Rev. 3.10 Unit diagnose bit added (date 03.03.12) *
;* da030406 Rev. 3.20 DPV1 file modification (date 03.10.21) *
;*****************************************************************************
#Profibus_DP
GSD_Revision = 3;
Vendor_Name = "DANFOSS DRIVES A/S";
Model_name = "FCD 300 3MB";
Revision = "Rev. 3.20";
Ident_Number = 0x0406;
Protocol_Ident = 0;
Station_type = 0;
FMS_supp = 0;
Hardware_Release = "4.0";
Software_Release = "1.43";
Bitmap_Device = "FCD300"
Slave_Family = 1@Danfoss@FCD300@DPV1;
Info_Text = "FCD 300 PROFIBUS DPV1";
9.6_supp = 1;
19.2_supp = 1;
93.75_supp = 1;
187.5_supp = 1;
500_supp = 1;
1.5M_supp = 1;
3M_supp = 1;
6M_supp = 0;
12M_supp = 0;
MaxTsdr_9.6 = 15;
MaxTsdr_19.2 = 15;
MaxTsdr_93.75 = 15;
MaxTsdr_187.5 = 15;
MaxTsdr_500 = 15;
MaxTsdr_1.5M = 25;
MaxTsdr_3M = 50;
Redundancy = 0;
24V_Pins = 0;
Freeze_Mode_supp = 1;
Sync_Mode_supp = 1;
Auto_Baud_supp = 1;
Set_Slave_add_supp = 1;
Min_Slave_Intervall = 10;
Modular_Station = 1;
Max_Module = 1;
Max_Input_Len = 28;
Max_Output_Len = 28;
Max_Data_Len = 56;
Max_Diag_Data_Len = 32;
Fail_Safe = 1
;
;DPV1 specific
;
User_Prm_Data_Len = 3;
User_Prm_Data = 0x00,0x00,0x00
DPV1_Slave = 1
C1_Read_Write_supp = 1
C2_Read_Write_supp = 1
C1_Max_Data_Len = 240
C2_Max_Data_Len = 240
C1_Response_Timeout = 100
C2_Response_Timeout = 100
C1_Read_Write_required = 0
C2_Read_Write_required = 0
C2_Max_Count_Channels = 3
Max_Initiate_PDU_Length = 52
DPV1_Data_Types = 0
WD_Base_1ms_supp = 1
Check_Cfg_Mode = 0
Publisher_supp = 1
;
; Unit Diagnosis: Warning word par. 540.
;
Unit_Diag_Bit(0) = "Info text for FCD 300";
Unit_Diag_Bit(1) = "Overflow SPM-FIFO";
Unit_Diag_Bit(2) = "Actual value is not updated";
Unit_Diag_Bit(3) = "Not used";
Unit_Diag_Bit(4) = "Not used";
Unit_Diag_Bit(5) = "Not used";
Unit_Diag_Bit(6) = "Not used";
Unit_Diag_Bit(7) = "See Manual for more information";
Unit_Diag_Bit(51) = "[W Bit51] HPFB bus timeout"
Unit_Diag_Bit(52) = "[W Bit52] Serial comm. timeout"
Unit_Diag_Bit(54) = "[W Bit54] Current limit"
Unit_Diag_Bit(55) = "[W Bit55] Motor thermistor"
Unit_Diag_Bit(40) = "[W Bit40] Motor overload"
Unit_Diag_Bit(41) = "[W Bit41] Inverter overload"
Unit_Diag_Bit(42) = "[W Bit42] Undervoltage"
Unit_Diag_Bit(43) = "[W Bit43] Overvoltage"
Unit_Diag_Bit(44) = "[W Bit44] Voltage warning low"
Unit_Diag_Bit(45) = "[W Bit45] Voltage warning high"
Unit_Diag_Bit(46) = "[W Bit46] Phase loss"
Unit_Diag_Bit(32) = "[W Bit32] Live zero error"
Unit_Diag_Bit(38) = "[W Bit38] Out of freq. range"
Unit_Diag_Bit(39) = "[W Bit39] Fieldbus com. fault"
Unit_Diag_Bit(30) = "[W Bit30] Switch mode warning"
Unit_Diag_Bit(31) = "[W Bit31] Heat sink temp. high"
;
; Unit Diagnosis: Extended Status word par. 541.
;
Unit_Diag_Bit(80) = "[S Bit80] Ramping"
Unit_Diag_Bit(81) = "[S Bit81] Auto. motor tuning"
Unit_Diag_Bit(82) = "[S Bit82] Start clkw/anti-clkw"
Unit_Diag_Bit(83) = "[S Bit83] Slow down"
Unit_Diag_Bit(84) = "[S Bit84] Catch-up"
Unit_Diag_Bit(85) = "[S Bit85] Feedback high"
Unit_Diag_Bit(86) = "[S Bit86] Feedback low"
Unit_Diag_Bit(87) = "[S Bit87] Output current high"
Unit_Diag_Bit(72) = "[S Bit72] Output current low"
Unit_Diag_Bit(73) = "[S Bit73] Output frequency high"
Unit_Diag_Bit(74) = "[S Bit74] Output frequency low"
Unit_Diag_Bit(77) = "[S Bit77] Braking"
Unit_Diag_Bit(79) = "[S Bit79] Out of freq. range"
Unit_Diag_Bit(60) = "[S Bit60] PB acyclic MSAC1 com."
Unit_Diag_Bit(61) = "[S Bit61] PB acyclic MSAC2 com."
;
; Unit Diagnosis: Alarm word par. 538.
;
Unit_Diag_Bit(113) = "[A Bit113] Trip locked"
Unit_Diag_Bit(114) = "[A Bit114] AMA tuning not OK"
Unit_Diag_Bit(118) = "[A Bit118] HPFP bus timeout"
Unit_Diag_Bit(119) = "[A Bit119] Standard bus timeout"
Unit_Diag_Bit(104) = "[A Bit104] Short-circuiting"
Unit_Diag_Bit(105) = "[A Bit105] Switchmode fault"
Unit_Diag_Bit(106) = "[A Bit106] Earth fault"
Unit_Diag_Bit(107) = "[A Bit107] Overcurrent"
Unit_Diag_Bit(109) = "[A Bit109] Motor thermistor"
Unit_Diag_Bit(110) = "[A Bit110] Motor overload"
Unit_Diag_Bit(111) = "[A Bit111] Inverter overload"
Unit_Diag_Bit(96) = "[A Bit96] Undervoltage"
Unit_Diag_Bit(97) = "[A Bit97] Overvoltage"
Unit_Diag_Bit(98) = "[A Bit98] Phase fault"
Unit_Diag_Bit(99) = "[A Bit99] Livezero error"
Unit_Diag_Bit(100) = "[A Bit100] Heat sink temp. high"
Unit_Diag_Bit(89) = "[A Bit89] Fieldbus com. fault"
Unit_Diag_Bit(91) = "[A Bit91] Inrush fault"
Unit_Diag_Bit(92) = "[A Bit92] Internal fault"
;
; Unit Diagnosis: Communication option warning word par. 953
;
Unit_Diag_Bit(128) = "Connection to master is not OK"
Unit_Diag_Bit(129) = "Not used"
Unit_Diag_Bit(130) = "FDL is not OK"
Unit_Diag_Bit(131) = "Clear data command received"
Unit_Diag_Bit(132) = "Actual value is not updated"
Unit_Diag_Bit(133) = "Spontaneous mes. FIFO overflow"
Unit_Diag_Bit(134) = "PROFIBUS ASIC is not transmit."
Unit_Diag_Bit(135) = "Init of PROFIBUS is not OK"
Unit_Diag_Bit(120) = "Not used"
Unit_Diag_Bit(121) = "Not used"
Unit_Diag_Bit(122) = "Not used"
Unit_Diag_Bit(123) = "Not used"
Unit_Diag_Bit(124) = "Error code during init: Bit 0"
Unit_Diag_Bit(125) = "Error code during init: Bit 1"
Unit_Diag_Bit(126) = "Error code during init: Bit 2"
Unit_Diag_Bit(127) = "Error code during init: Bit 3"
;
;Modules
;
Module = "PPO Typ 1 Module consistent PCD" 0xF3, 0xF1;
1
EndModule;
Module = "PPO Typ 1 Word consistent PCD " 0xF3, 0x71;
2
EndModule;
Module = "PPO Typ 2 Module consistent PCD" 0xF3, 0xF5;
3
EndModule;
Module = "PPO Typ 2 Word consistent PCD " 0xF3, 0x75;
4
EndModule;
Module = "PPO Typ 3 Module consistent PCD" 0xF1;
5
EndModule;
Module = "PPO Typ 3 Word consistent PCD " 0x71;
6
EndModule;
Module = "PPO Typ 4 Module consistent PCD" 0xF5;
7
EndModule;
Module = "PPO Typ 4 Word consistent PCD " 0x75;
8
EndModule;
Module = "PPO Typ 5 Module consistent PCD" 0xF3, 0xF9;
9
EndModule;
Module = "PPO Typ 5 Word consistent PCD " 0xF3, 0x79;
10
EndModule;
Module = "PPO Typ 6 Module consistent PCD" 0xF3;
11
EndModule;
Module = "PPO Typ 6 Word consistent PCD " 0x73;
12
EndModule;
Module = "PPO Typ 7 Module consistent PCD" 0xF7;
13
EndModule;
Module = "PPO Typ 7 Word consistent PCD " 0x77;
14
EndModule;
Module = "PPO Typ 8 Module consistent PCD" 0xF9;
15
EndModule;
Module = "PPO Typ 8 Word consistent PCD " 0x79;
16
EndModule;