?? functaumg369xb_configuremasterslaveoperation.html
字號(hào):
<!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML 4.01 Transitional//EN">
<html>
<head>
<meta http-equiv="Content-Type" content="text/html; charset=ISO-8859-1">
<link rel="stylesheet" href="htmlhelp.css" type="text/css">
<title>aumg369xb_configureMasterSlaveOperation</title>
</head>
<body>
<h1>aumg369xb_configureMasterSlaveOperation</h1>
<p class="syntax">
ViStatus aumg369xb_configureMasterSlaveOperation (ViSession instrumentHandle,
ViBoolean masterSlaveEnabled,
ViReal64 slaveDeltaFrequency_Hz,
ViReal64 slaveL1,
ViReal64 slaveL2);
</p>
<h2 class="purpose">Purpose</h2>
<p class="body">
This function turns on or turns off the master-slave mode of operation. If the master-slave mode is turned on, this function configures the slave delta frequency, the slave main power level and the slave alternate sweep power level.
</p>
<h2>Parameters</h2>
<table class="borderless" summary="Parameter help">
<tr>
<td valign="top"><em class="label">Input</em></td>
</tr>
<tr>
<td class="tablehead">Name</td>
<td class="tablehead">Type</td>
<td class="tablehead">Description</td>
</tr>
<tr>
<td class="paramName">instrumentHandle</td>
<td class="paramDataType">ViSession</td>
<td>
<p class="body">
This control accepts the Instrument Handle returned by the Initialize function to select the desired instrument driver session.
<br/>
Default Value: None
</p>
</td>
</tr>
<tr>
<td class="paramName">masterSlaveEnabled</td>
<td class="paramDataType">ViBoolean</td>
<td>
<p class="body">
Turns on or turns off the master-slave mode of operation.
<br/>
Valid Values:
<br/>
VI_FALSE - Off (Default)
<br/>
VI_TRUE - On
<br/>
Notes:
<br/>
Master-slave operation provides for enabling two MG369XBs that are connected in a master-slave configuration to produce CW and synchronized, swept output signals at a frequency offset. In a master-slave configuration, one instrument (the master) controls the other (the slave) via interface cables between their rear panel AUX I/O and SERIAL I/O connectors. The two units are phase-locked together by connecting them to the same 10 MHz reference time base.
</p>
</td>
</tr>
<tr>
<td class="paramName">slaveDeltaFrequency_Hz</td>
<td class="paramDataType">ViReal64</td>
<td>
<p class="body">
Sets the delta-F frequency parameter for the slave MG369XB unit.
<br/>
Valid Range: Frequency range of the slave MG369XB model.
<br/>
Default Value: 1.0E9
<br/>
Unit: HZ
<br/>
Model Number Configuration Frequency Range
<br/>
-------------------------------------------------------
<br/>
MG3691B With Option 4 or 5 0.01 - 10.0 GHz
<br/>
Standard 2.0 - 10.0 GHz
<br/>
-------------------------------------------------------
<br/>
MG3692B With Option 4 or 5 0.01 - 20.0 GHz
<br/>
Standard 2.0 - 20.0 GHz
<br/>
-------------------------------------------------------
<br/>
MG3693B With Option 4 or 5 0.01 - 30.0 GHz
<br/>
Standard 2.0 - 30.0 GHz
<br/>
-------------------------------------------------------
<br/>
MG3694B With Option 4 or 5 0.01 - 40.0 GHz
<br/>
Standard 2.0 - 40.0 GHz
<br/>
-------------------------------------------------------
<br/>
MG3695B With Option 4 or 5 0.01 - 50.0 GHz
<br/>
Standard 2.0 - 50.0 GHz
<br/>
-------------------------------------------------------
<br/>
MG3696B With Option 4 or 5 0.01 - 67.0 GHz
<br/>
Standard 2.0 - 67.0 GHz
</p>
</td>
</tr>
<tr>
<td class="paramName">slaveL1</td>
<td class="paramDataType">ViReal64</td>
<td>
<p class="body">
Sets the main power level parameter (L1) of the slave unit.
<br/>
Valid Range: Power level range of the slave MG369XB model..
<br/>
Default Value: 0.0
<br/>
Units: DM (Log), VT (Linear)
</p>
</td>
</tr>
<tr>
<td class="paramName">slaveL2</td>
<td class="paramDataType">ViReal64</td>
<td>
<p class="body">
Sets the alternate sweep power level parameter (L2) of the slave unit.
<br/>
Valid Range: Power level range of the slave MG369XB model..
<br/>
Default Value: 0.0
<br/>
Units: DM (Log), VT (Linear)
</p>
</td>
</tr>
</table>
<h2>Return Value</h2>
<table class="borderless" summary="Return value help">
<tr>
<td class="tablehead">Name</td>
<td class="tablehead">Type</td>
<td class="tablehead">Description</td>
</tr>
<tr>
<td class="paramName">status</td>
<td class="paramDataType">ViStatus</td>
<td>
<p class="body">
This control contains the status code returned by the function call.
<br/>
Status Codes:
<br/>
Status Description
<br/>
-------------------------------------------------
<br/>
0 No error (the call was successful).
<br/>
3FFC0101 ID Query not supported - VI_WARN_NSUP_ID_QUERY
<br/>
3FFC0102 Reset not supported - VI_WARN_NSUP_RESET
<br/>
3FFC0103 Self Test not supported - VI_WARN_NSUP_SELF_TEST
<br/>
3FFC0104 Error Query not supported - VI_WARN_NSUP_ERROR_QUERY
<br/>
3FFC0105 Revision Query not supported - VI_WARN_NSUP_REV_QUERY
<br/>
3FFF0005 The specified termination character was read.
<br/>
3FFF0006 The specified number of bytes was read.
<br/>
BFFC0001 Parameter 1 out of range.
<br/>
BFFC0002 Parameter 2 out of range.
<br/>
BFFC0003 Parameter 3 out of range.
<br/>
BFFC0004 Parameter 4 out of range.
<br/>
BFFC0005 Parameter 5 out of range.
<br/>
BFFC0006 Parameter 6 out of range.
<br/>
BFFC0007 Parameter 7 out of range.
<br/>
BFFC0008 Parameter 8 out of range.
<br/>
BFFC0011 Instrument returned invalid response to ID Query
<br/>
BFFF0000 Miscellaneous or system error occurred.
<br/>
BFFF000E Invalid session handle.
<br/>
BFFF0015 Timeout occurred before operation could complete.
<br/>
BFFF0034 Violation of raw write protocol occurred.
<br/>
BFFF0035 Violation of raw read protocol occurred.
<br/>
BFFF0036 Device reported an output protocol error.
<br/>
BFFF0037 Device reported an input protocol error.
<br/>
BFFF0038 Bus error occurred during transfer.
<br/>
BFFF003A Invalid setup (attributes are not consistent).
<br/>
BFFF005F No listeners condition was detected.
<br/>
BFFF0060 This interface is not the controller in charge.
<br/>
BFFF0067 Operation is not supported on this session.
<br/>
Notes:
<br/>
(1) Parameter Error Codes for parameters 1 through 8 are defined in the vpptype.h header file the range is BFFC0001 - BFFC0008;
</p>
</td>
</tr>
</table>
<h2>References</h2>
<p class="body">
<a href="ClassFrequency.html">Frequency</a><br/>
<a href="ClassConfiguration%20Functions.html">Configuration Functions</a><br/>
<a href="Anritsu%20MG369XB%20Synthesizer.html">Anritsu MG369XB Synthesizer</a><br/>
<a href="Alphabetical%20Function%20Index.html">Alphabetical Function Index</a><br/>
<a href="Hierarchical%20Function%20Index.html">Hierarchical Function Index</a><br/>
</p>
</body>
</html>
?? 快捷鍵說(shuō)明
復(fù)制代碼
Ctrl + C
搜索代碼
Ctrl + F
全屏模式
F11
切換主題
Ctrl + Shift + D
顯示快捷鍵
?
增大字號(hào)
Ctrl + =
減小字號(hào)
Ctrl + -