?? step.pid
字號:
# step.pid
#
# shows the step function response with a 10%
# step in "manual mode", that is using the
# constant bias parameter only
#
# sets the Set point value the same as the
# desired output, even though it has no
# real effect, so my plot capture routine
# picks it up and it shows in the illustration
#
# Copyright (C) 2000 Jack Klein
# Macmillan Computer Publishing
#
# ordinary parameters, set before execution begins
P=0 Proportional gain
I=0 Integral gain
D=0 Derivative gain
H=0 output Hold
A=0 Acceleration feed forward
F=0 Friction feed forward
V=0 Velocity feed forward
B=20 constant Bias
R=0 acceleration Rate
S=20 Set point
T=1 Transfer ratio
L=0.368 response Lag
N=-100 miNimum output
M=100 Maximum output
W=0 sleW limit
# execute 51 cycles altogether, 11 with the
# original parameters to allow the output to settle
Y=51 cYcle count
# now events triggered after 11 cycles
# change the constant Bias and Set point
# both from 20 to 30, a 10% step and turn
# on the P with a high gain
@11 S=30 Set point
@11 P=1.9 Proportional gain
# finished 51 cycles, time to quit
@51 Q Quit