?? iana-printer-mib
字號:
-- Fujitsu Printer Language
-- Reference Manual:
-- "FM Printer Sequence" No. 80HP-0770
-- FUJITSU LIMITED
langCGM(60), -- Not in RFC 1759
-- Computer Graphics Metafile
-- MIME type 'image/cgm'
langJPEG(61), -- Not in RFC 1759
-- Joint Photographic Experts Group
-- MIME type 'image/jpeg'
langCALS1(62), -- Not in RFC 1759
-- US DOD CALS1 (see MIL-STD-1840)
-- MIME type 'application/cals-1840'
langCALS2(63), -- Not in RFC 1759
-- US DOD CALS2 (see MIL-STD-1840)
-- MIME type 'application/cals-1840'
langNIRS(64), -- Not in RFC 1759
-- US DOD NIRS (see MIL-STD-1840)
-- MIME type 'application/cals-1840'
langC4(65) -- Not in RFC 1759
-- US DOD C4 (see MIL-STD-1840)
-- MIME type 'application/cals-1840'
}
--
-- Input/Output Group TEXTUAL-CONVENTIONs
--
PrtInputTypeTC ::= TEXTUAL-CONVENTION
-- This TC was extracted from prtInputType in RFC 1759.
STATUS current
DESCRIPTION
"The type of technology (discriminated primarily according to
feeder mechanism type) employed by a specific component or
components."
SYNTAX INTEGER {
other(1),
unknown(2),
sheetFeedAutoRemovableTray(3),
sheetFeedAutoNonRemovableTray(4),
sheetFeedManual(5),
continuousRoll(6),
continuousFanFold(7)
}
PrtOutputTypeTC ::= TEXTUAL-CONVENTION
-- This TC was extracted from prtOutputType in RFC 1759.
STATUS current
DESCRIPTION
"The Type of technology supported by this output subunit."
SYNTAX INTEGER {
other(1),
unknown(2),
removableBin(3),
unRemovableBin(4),
continuousRollDevice(5),
mailBox(6),
continuousFanFold(7)
}
--
-- Marker Group TEXTUAL-CONVENTIONs
--
PrtMarkerMarkTechTC ::= TEXTUAL-CONVENTION
-- This TC was extracted from prtMarkerMarkTech in RFC 1759.
STATUS current
DESCRIPTION
"The type of marking technology used for this marking
subunit."
SYNTAX INTEGER {
other(1),
unknown(2),
electrophotographicLED(3),
electrophotographicLaser(4),
electrophotographicOther(5),
impactMovingHeadDotMatrix9pin(6),
impactMovingHeadDotMatrix24pin(7),
impactMovingHeadDotMatrixOther(8),
impactMovingHeadFullyFormed(9),
impactBand(10),
impactOther(11),
inkjetAqueous(12),
inkjetSolid(13),
inkjetOther(14),
pen(15),
thermalTransfer(16),
thermalSensitive(17),
thermalDiffusion(18),
thermalOther(19),
electroerosion(20),
electrostatic(21),
photographicMicrofiche(22),
photographicImagesetter(23),
photographicOther(24),
ionDeposition(25),
eBeam(26),
typesetter(27)
}
PrtMarkerSuppliesTypeTC ::= TEXTUAL-CONVENTION
-- This TC was extracted from prtMarkerSuppliesType in RFC 1759.
STATUS current
DESCRIPTION
"The type of this supply."
SYNTAX INTEGER {
other(1),
unknown(2),
-- Values for Printer MIB
toner(3),
wasteToner(4),
ink(5),
inkCartridge(6),
inkRibbon(7),
wasteInk(8),
opc(9), -- photo conductor
developer(10),
fuserOil(11),
solidWax(12),
ribbonWax(13),
wasteWax(14),
fuser(15), -- Not in RFC 1759
coronaWire(16), -- Not in RFC 1759
fuserOilWick(17), -- Not in RFC 1759
cleanerUnit(18), -- Not in RFC 1759
fuserCleaningPad(19), -- Not in RFC 1759
transferUnit(20), -- Not in RFC 1759
tonerCartridge(21), -- Not in RFC 1759
fuserOiler(22), -- Not in RFC 1759
-- End of values for Printer MIB
-- Values for Finisher MIB
water(23), -- Not in RFC 1759
wasteWater(24), -- Not in RFC 1759
glueWaterAdditive(25),-- Not in RFC 1759
wastePaper(26), -- Not in RFC 1759
bindingSupply(27), -- Not in RFC 1759
bandingSupply(28), -- Not in RFC 1759
stitchingWire(29), -- Not in RFC 1759
shrinkWrap(30), -- Not in RFC 1759
paperWrap(31), -- Not in RFC 1759
staples(32), -- Not in RFC 1759
inserts(33), -- Not in RFC 1759
covers(34) -- Not in RFC 1759
-- End of values for Finisher MIB
}
--
-- Media Path TEXTUAL-CONVENTIONs
--
PrtMediaPathTypeTC ::= TEXTUAL-CONVENTION
-- This TC was extracted from prtMediaPathType in RFC 1759.
STATUS current
DESCRIPTION
"The type of the media path for this media path."
SYNTAX INTEGER {
other(1),
unknown(2),
longEdgeBindingDuplex(3),
shortEdgeBindingDuplex(4),
simplex(5)
}
--
-- Console Group TEXTUAL-CONVENTIONs
--
PrtConsoleColorTC ::= TEXTUAL-CONVENTION
-- This TC was extracted from prtConsoleColor in RFC 1759.
STATUS current
DESCRIPTION
"The color of this light."
SYNTAX INTEGER {
other(1),
unknown(2),
white(3),
red(4),
green(5),
blue(6),
cyan(7),
magenta(8),
yellow(9),
orange(10) -- Not in RFC 1759
}
PrtConsoleDisableTC ::= TEXTUAL-CONVENTION
-- This TC was extracted from prtConsoleDisable in RFC 1759.
STATUS current
DESCRIPTION
"This value indicates whether or not input is accepted from
the operator console. A value of 'enabled' indicates that
input is accepted from the console, and a value of 'disabled'
indicates that input is not accepted from the console. "
SYNTAX INTEGER {
enabled(3),
disabled(4)
}
--
-- Alert Group TEXTUAL-CONVENTIONs
--
PrtAlertTrainingLevelTC ::= TEXTUAL-CONVENTION
-- This TC was extracted from prtAlertTrainingLevel in RFC 1759.
STATUS current
DESCRIPTION
"The level of training required to handle this alert, if
human intervention is required. The noInterventionRequired
value should be used if the event does not require any human
intervention. The training level is an enumeration that is
determined and assigned by the printer manufacturer based on
the information or training required to handle this alert.
The printer will break alerts into these different training
levels. It is the responsibility of a management application
in the system to determine how a particular alert is handled
and how and to whom that alert is routed. The following are
the four training levels of alerts:
Field Service - Alerts that typically require advanced
training and technical knowledge of the printer and its
subunits. An example of a technical person would be a
manufacturer's Field Service representative, or other
person formally trained by the manufacturer or similar
representative.
Trained - Alerts that require an intermediate or moderate
knowledge of the printer and its subunits. A typical
example of such an alert is replacing a toner cartridge.
Untrained - Alerts that can be fixed without prior
training either because the action to correct the alert
is obvious or the printer can help the untrained person
fix the problem. A typical example of such an alert is
reloading paper trays or emptying output bins on a low
end printer.
Management - Alerts that have to do with overall operation
of and configuration of the printer. Examples of such
management events are configuration change of subunits."
SYNTAX INTEGER {
other(1),
unknown(2),
untrained(3),
trained(4),
fieldService(5),
management(6),
noInterventionRequired(7) -- Not in RFC 1759
}
PrtAlertGroupTC ::= TEXTUAL-CONVENTION
-- Values in the range 1 to 29 must not be IANA-assigned without
-- re-publishing Printer MIB.
-- Values of 30 and greater are for use in MIBs that augment
-- the Printer MIB, such as the Finisher MIB.
-- This TC extracted from prtAlertGroup in RFC 1759.
STATUS current
DESCRIPTION
"The type of subunit within the printer model that this alert
is related. Input, output, and markers are examples of
printer model groups, i.e., examples of types of subunits.
Wherever possible, the enumerations match the sub-identifier
that identifies the relevant table in the Printer MIB.
?? 快捷鍵說明
復制代碼
Ctrl + C
搜索代碼
Ctrl + F
全屏模式
F11
切換主題
Ctrl + Shift + D
顯示快捷鍵
?
增大字號
Ctrl + =
減小字號
Ctrl + -