?? printer-mib
字號(hào):
SYNTAX INTEGER { unknown(2), firstToLast(3), lastToFirst(4) }PrtOutputPageDeliveryOrientationTC ::= TEXTUAL-CONVENTION -- This TC was extracted from prtOutputPageDeliveryOrientation -- in RFC 1759. STATUS current DESCRIPTION "The reading surface that will be 'up' when pages are delivered to the associated output sub-unit. Values are Face-Up and Face Down (Note: interpretation of these values is, in general, context-dependent based on locale; presentation of these values to an end-user should be normalized to the expectations of the user." SYNTAX INTEGER { faceUp(3), faceDown(4) }---- Marker Group TEXTUAL-CONVENTIONs--PrtMarkerCounterUnitTC ::= TEXTUAL-CONVENTION -- This TC was extracted from prtMarkerCounterUnit in RFC 1759. STATUS current DESCRIPTION "The unit that will be used by the printer when reporting counter values for this marking sub-unit. The time units of measure are provided for a device like a strip recorder that does not or cannot track the physical dimensions of the media and does not use characters, lines or sheets." SYNTAX INTEGER { tenThousandthsOfInches(3), -- .0001 micrometers(4), characters(5), lines(6), impressions(7), sheets(8), dotRow(9), hours(11), feet(16), meters(17) }PrtMarkerSuppliesSupplyUnitTC ::= TEXTUAL-CONVENTION -- This TC was extracted from prtMarkerSuppliesSupplyUnit -- in RFC 1759. STATUS current DESCRIPTION "Unit of this marker supply container/receptacle." SYNTAX INTEGER { other(1), -- New, not in RFC 1759 unknown(2), -- New, not in RFC 1759 tenThousandthsOfInches(3), -- .0001 micrometers(4), impressions(7), -- New, not in RFC 1759 sheets(8), -- New, not in RFC 1759 hours(11), -- New, not in RFC 1759 thousandthsOfOunces(12), tenthsOfGrams(13), hundrethsOfFluidOunces(14), tenthsOfMilliliters(15), feet(16), -- New, not in RFC 1759 meters(17), -- New, not in RFC 1759 -- Values for Finisher MIB items(18), -- e.g., #staples. New, not in RFC 1759 percent(19) -- New, not in RFC 1759 }PrtMarkerSuppliesClassTC ::= TEXTUAL-CONVENTION -- This TC was extracted from prtMarkerSuppliesClass in RFC 1759. STATUS current DESCRIPTION "Indicates whether this supply entity represents a supply that is consumed or a receptacle that is filled." SYNTAX INTEGER { other(1), supplyThatIsConsumed(3), receptacleThatIsFilled(4) }PrtMarkerColorantRoleTC ::= TEXTUAL-CONVENTION -- This TC was extracted from prtMarkerColorantRole in RFC 1759. STATUS current DESCRIPTION "The role played by this colorant." SYNTAX INTEGER { -- Colorant Role other(1), process(3), spot(4) }PrtMarkerAddressabilityUnitTC ::= TEXTUAL-CONVENTION -- This TC was extracted from prtMarkerAddressabilityUnit -- in RFC 1759. STATUS current DESCRIPTION "The unit of measure of distances, as applied to the marker's resolution." SYNTAX INTEGER { tenThousandthsOfInches(3), -- .0001 micrometers(4) }---- Media Path TEXTUAL-CONVENTIONs--PrtMediaPathMaxSpeedPrintUnitTC ::= TEXTUAL-CONVENTION -- This TC was extracted from prtMediaPathMaxSpeedPrintUnit -- in RFC 1759. STATUS current DESCRIPTION "The unit of measure used in specifying the speed of all media paths in the printer." SYNTAX INTEGER { tenThousandthsOfInchesPerHour(3),-- .0001/hour micrometersPerHour(4), charactersPerHour(5), linesPerHour(6), impressionsPerHour(7), sheetsPerHour(8), dotRowPerHour(9), feetPerHour(16), metersPerHour(17) }---- Interpreter Group TEXTUAL-CONVENTIONs--PrtInterpreterTwoWayTC ::= TEXTUAL-CONVENTION -- This TC was extracted from prtInterpreterTwoWay in RFC 1759. STATUS current DESCRIPTION "Indicates whether or not this interpreter returns information back to the host." SYNTAX INTEGER { yes(3), no(4) }---- Alert Group TEXTUAL-CONVENTIONs--PrtAlertSeverityLevelTC ::= TEXTUAL-CONVENTION -- This TC was extracted from prtAlertSeverityLevel in RFC 1759. STATUS current DESCRIPTION "The level of severity of this alert table entry. The printer determines the severity level assigned to each entry in the table. A critical alert is binary by nature and definition. A warning is defined to be a non-critical alert. The original and most common warning is unary. The binary warning was added later and given a more distinguished name." SYNTAX INTEGER { other(1), critical(3), warning(4), warningBinaryChangeEvent(5) -- New, not in RFC 1759 }-- The General Printer Group---- The general printer sub-unit is responsible for the overall-- control and status of the printer. There is exactly one-- general printer sub-unit in a printer.prtGeneral OBJECT IDENTIFIER ::= { printmib 5 }prtGeneralTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtGeneralEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of general information per printer. Objects in this table are defined in various places in the MIB, nearby the groups to which they apply. They are all defined here to minimize the number of tables that would otherwise need to exist." ::= { prtGeneral 1 }prtGeneralEntry OBJECT-TYPE SYNTAX PrtGeneralEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry exists in this table for each device entry in the host resources MIB device table with a device type of 'printer'. NOTE: The above description has been modified from RFC 1759 for clarification." INDEX { hrDeviceIndex } ::= { prtGeneralTable 1 }PrtGeneralEntry ::= SEQUENCE { -- Note that not all of the objects in this sequence are in -- the general printer group. The group to which an -- object belongs is tagged with a label "General", "Input" -- "Output", etc. after each entry in the following sequence. -- prtGeneralConfigChanges Counter32, -- General prtGeneralCurrentLocalization Integer32, -- General prtGeneralReset PrtGeneralResetTC, -- General prtGeneralCurrentOperator OCTET STRING, -- Responsible Party prtGeneralServicePerson OCTET STRING, -- Responsible Party prtInputDefaultIndex Integer32, -- Input prtOutputDefaultIndex Integer32, -- Output prtMarkerDefaultIndex Integer32, -- Marker prtMediaPathDefaultIndex Integer32, -- Media Path prtConsoleLocalization Integer32, -- Console prtConsoleNumberOfDisplayLines Integer32, -- Console prtConsoleNumberOfDisplayChars Integer32, -- Console prtConsoleDisable PrtConsoleDisableTC, -- Console, prtAuxiliarySheetStartupPage PresentOnOff, -- AuxiliarySheet prtAuxiliarySheetBannerPage PresentOnOff, -- AuxiliarySheet prtGeneralPrinterName OCTET STRING, -- General V2 prtGeneralSerialNumber OCTET STRING, -- General V2 prtAlertCriticalEvents Counter32, -- Alert V2 prtAlertAllEvents Counter32 -- Alert V2 }prtGeneralConfigChanges OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Counts configuration changes within the printer. A configuration change is defined to be an action that results in a change to any MIB object other than those that reflect status or level, or those that act as counters or gauges. In addition, any action that results in a row being added or deleted from any table in the Printer MIB is considered a configuration change. Such changes will often affect the capability of the printer to service certain types of print jobs. Management applications may cache infrequently changed configuration information about sub units within the printer. This object should be incremented whenever the agent wishes to notify management applications that any cached configuration information for this device is to be considered 'stale'. At this point, the management application should flush any configuration information cached about this device and fetch new configuration information. The following are examples of actions that would cause the prtGeneralConfigChanges object to be incremented: - Adding an output bin - Changing the media in a sensing input tray - Changing the value of prtInputMediaType Note that the prtGeneralConfigChanges counter would not be incremented when an input tray is temporarily removed to load additional paper or when the level of an input device changes. NOTE: The above description has been modified from RFC 1759 for clarification." ::= { prtGeneralEntry 1 }prtGeneralCurrentLocalization OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the prtLocalizationIndex corresponding to the current language, country, and character set to be used for localized string values that are identified as being dependent on the value of this object. Note that this object does not apply to localized strings in the prtConsole group or to any object that is not explicitly identified as being localized according to prtGeneralCurrentLocalization. When an object's 'charset' is controlled by the value of prtGeneralCurrentLocalization, it MUST specify PrtLocalizedDescriptionStringTC as its syntax. NOTE: The above description has been modified from RFC 1759 for clarification." ::= { prtGeneralEntry 2 }prtGeneralReset OBJECT-TYPE -- NOTE: In RFC 1759, the enumeration values were implicitly defined -- by this object. SYNTAX PrtGeneralResetTC MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this value to 'powerCycleReset', 'resetToNVRAM', or 'resetToFactoryDefaults' will result in the resetting of the printer. When read, this object will always have the value 'notResetting(3)', and a SET of the value 'notResetting' shall have no effect on the printer. Some of the defined values are optional. However, every implementation must support at least the values 'notResetting' and 'resetToNVRAM'." ::= { prtGeneralEntry 3 }-- The Responsible Party groupprtGeneralCurrentOperator OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..127)) MAX-ACCESS read-write STATUS current DESCRIPTION "The name of the person who is responsible for operating this printer. It is suggested that this string include information that would enable other humans to reach the operator, such as a phone number. As a convention to facilitate automatic notification of the operator by the agent or network management station, the phone number, fax number or email address should be indicated by the URL schemes 'tel:', 'fax:' and 'mailto:', respectively. If either the phone, fax, or email information is not available, then a line should not be included for this information. NOTE: For interoperability purposes, it is advisable to use email addresses formatted according to [RFC2822] requirements.
?? 快捷鍵說(shuō)明
復(fù)制代碼
Ctrl + C
搜索代碼
Ctrl + F
全屏模式
F11
切換主題
Ctrl + Shift + D
顯示快捷鍵
?
增大字號(hào)
Ctrl + =
減小字號(hào)
Ctrl + -