TROUBLESHOOTING SIMPLE NETWORK PROBLEMS IN TORNADO 2.0
------------------------------------------------------
If you are new to Tornado 2.0, or you are booting a target for
the first time, or if the target booted successfully, but does
not respond to pings, please read basicNetConfiguration article.
basicNetConfiguration contains instructions on how to configure a
kernel with a target shell and network debugging libraries. It
contains information to avoid errors like:
rpccore backend client RPC: Timed out
Network interface unknown
muxDevLoad failed for device entry
wdbConfig: error configuring WDB communication interface
Error loading file: errno = 0xd0003
If target responded to pings initially, and after running your
socket application (or a library that uses the network such as
the FTP server), applications sputter or hang for a while and
then resume, please read netPerformance article. It gives an
overview of vxWorks network internals and configuration issues
that impact performance.
This article assumes that a target has booted successfully and
responds to pings initially. You are either running demo code
from WindSuf->Demo Code->Networking or your own application.
At some point, the target does not respond to pings anymore, or
network performance is slow. At this point from the target shell,
verify that tNetTask is still running at priority 50.
If i shows tNetTask as suspended, call tt tNetTask.
There might be a reference to a null pointer somewhere, or an
unitialized interrupt. If this error occurs with a default
configuration, you have not added third party network drivers, or
software, your application is not running, and you are just using
WRS software on a supported BSP, please contact:
support@windriver.com.
If application runs fine, but as you increase the number of
sockets or the packet rate, the application sputters or hangs,
run the show functions described below from the target shell
AFTER the target boots and AFTER the problem occurs.
->netStackSysPoolShow
Network stack system memory pool status
->netStackDataPoolShow
Network stack data memory pool status
->i
which tasks are running, show priorities
->inetstatShow
shows sockets and their receive queues
->ipstatShow
show IP protocol statistics
->tcpstatShow
show TCP protocol statistics
->udpstatShow
show UDP protocol statistics
->icmpstatShow
show ICMP protocol statistics
-->mRouteShow
show route table, including masks
->routeShow
show route table without masks
->iosFdShow
show file descriptors
->arpShow
show ARP table contents
->hostShow
show host table content
>ifShow
show interfaces attached to IP. This function will show
END and BSD44 drivers.
->muxShow
show END drivers successfully loaded in the MUX
->endPoolShow("name", 0)
END driver memory pool status of driver "name"
For example: endPoolShow("fei", 0)
endPoolShow is not part of the API. This utility is
found in utilities.c
SYMPTOMS:
A. ENOBUFS
SOCKET APPLICATION SPUTTERS
If the network stack or driver memory pool sizes are too small,
applications will appear to hang and recover within minutes as
resources are freed. Errors like ENOBUFS, or
S_netBufLib_NO_POOL_MEMORY may occur.
The problem is most likely insufficient network stack and
driver buffer pool. Call netStackSysPoolShow and
netStackDataPoolShow. Increase the default allocation if
there are 0 free buffers available. Increase the driver's
buffer pool, and IP configuration parameters as indicated
in netPerformance.
B. TARGET STOPS RESPONDING TO PINGS.
RPC CORE BACKEND TIMEOUT REPORTED IN TARGET SERVER WINDOW
1. APPLICATION/DRIVER BUFFER LOANING PROBLEMS
If sockets buffers are not being read, driver buffers will be
depleted. As long as the driver is out of buffers, the driver
will not be able to receive or send packets. Pings will be
unanswered. Target server will be unable to contact the
target.
muxShow displays END drivers only. If the boot device (or the
other parameter if boot device is floppy, ata...) is listed
in muxShow, the driver version used is END.
ifShow displays both END and BSD 4.4 drivers.
endPoolShow displays END driver's buffer pool status. If
there are 0 free buffers, use inetstatShow to determine which
socket has data in the receive queue. This information can
be used to identify which task is not reading its sockets.
See netPerformance for an explanation of network driver
buffer loaning scheme.
2. DRIVER PROBLEMS
If inetstatShow shows no data in the receive queue, the
problem may be due to a faulty driver:
If you are using the END driver version, try the BDS44 version
(if available), and vice-versa. If the BSP supports more than
1 network card type, try a different card. If muxShow does not
show any drivers, BSD44 drivers are configured. BSD44 drivers
are configured if EITHER T101 build method is used, and
INCLUDE_END is undefined in config.h OR in T2 Project
facility:
network components->network devices->End attach interface and
End interface support components are excluded.
See basicNetConfiguration document for information on
configuring drivers. If changing drivers works, report
the problem to support@windriver.com.
Check WindSurf->Resolve to check Problem Lists and Keyword
Search.
If there are no other driver versions you can use, use the
loopback driver. Run both the server and the client code in
the target. Send to IP address 127.0.0.1.
C. TARGER RESPONDS TO PINGS, BUT DATA TRANSFER STOPS
If the target responds to pings, but data transfer stops, call
inetstatShow on the target and the corresponding function
(usually netstat) on the other host. If there is data backed
up in the send side and on the receive side on the other side,
most likely there is a deadlock situation within the
client/server application code. Check if deadlock does not
occur if you reduce the message size below 1460 bytes.
(For TCP). TCP is a stream of bytes. Loops are required
to read or write, since TCP can return partial reads and
partial writes.
D. APPLICATION WORKS BUT NETWORK PERFORMANCE IS SLOW
See netPerformance article.
E. PROTOCOL PROBLEMS
Check the before and after protocol error statistics show
routines for clues as to which error is increasing. Please
read Section 1.4.1 of NetPerformance article for an
explanation on UDP full sockets.
F. PRIORITY PROBLEMS
Make sure that tNetTask has a higher priority than application
tasks depending on the network. Please read Section 1.2 of
netPerformance article.
G. HARDWARE OR DRIVER MISCONFIGURATION PROBLEMS
1. Try changing the network card or using a different card.
Examine hub's LED. Verify that the LED shows activity for
the driver.
2. Configure the BSD44 driver version, if available. Call
ifShow to determine if there are collisions, CRC ... The end
driver does not report this information. If the driver
reports excessive collisions make sure that another node in
the network is not in full duplex mode.
3. If there are broadcast storms, verify that ifShow does not
show driver is in PROMISCUOUS mode.
------_extPart_000_01C0FFDE.1E130740
Content-Type: application/octet-stream;
nametilities.c"
Content-Transfer-Encoding: quoted-printable
Content-Disposition: attachment;
filenametilities.c"
/*********
?? 快捷鍵說明
復制代碼
Ctrl + C
搜索代碼
Ctrl + F
全屏模式
F11
切換主題
Ctrl + Shift + D
顯示快捷鍵
?
增大字號
Ctrl + =
減小字號
Ctrl + -