?? calsetup.txt
字號:
# calsetup file updated for eeprom version 3.3, ART version 2.4# General InfoCOUNTRY_OR_DOMAIN_FLAG = 0; # 1 indicates the code is a country code. 0=>regulatory domain codeWORLD_WIDE_ROAMING_FLAG = 0; # 1 indicates a single SKU covering worldwide roamingCOUNTRY_OR_DOMAIN_CODE = 0x000; # 12-bit country or domain code for intended region-of-use (hex) SUB_VENDOR_ID = 0x168C; # SubVendor ID in hexMACID_FILENAME = K:\ART\macid.txt; # central macID fileCUSTOMER_DEBUG = 1; # not to be turned on in normal operation.SHOW_TIMING_REPORT = 1; # show time taken by various testsATHEROS_LOGGING_SCHEME = 1; # Enable the Atheros specific label scheme # Instrumentation Info USE_INSTRUMENTS = 1; # Select whether Instruments are Connected PM_MODEL = 1; # 1 => HP 436A, 2 => Agilent E4416A, 3 => 4531SA_MODEL = 2;PM_GPIB_ADDR = 13; # Power meter GPIB Address SA_GPIB_ADDR = 18; # Spectrum analyzer GPIB Address ATT_GPIB_ADDR = 8; # Attenuator GPIB Address GOLDEN_IP_ADDR = 192.168.1.210; # IP addr of the golden machine#GOLDEN_IP_ADDR = .; # Use . if both DUT and GU are control by same machine # Calibration Setup Info CASE_TEMPERATURE = 45; # Case temperature of the AR5111 on the DUT during calibration (int)GOLDEN_PPM = -3; # Measured PPM of golden device (int)ATTEN_DUT_SA = 14; # Attenuation at 5.5GHz between DUT and spectrum analyzer (double)ATTEN_FIXED_DUT_GOLDEN = 20; # Fixed attenuation at 5.5GHz between DUT and GOLDEN (double)ATTEN_DUT_PM = 22; # Attenuation at 5.5GHz between DUT and power meter (double)11b_ATTEN_DUT_SA = 13; # Attenuation at 2.5GHz between DUT and spectrum analyzer (double)11b_ATTEN_FIXED_DUT_GOLDEN = 19; # Fixed attenuation at 2.5GHz between DUT and GOLDEN (double)11b_ATTEN_DUT_PM = 21; # Attenuation at 2.5GHz between DUT and power meter (double)# Test MarginsNUM_MASK_FAIL_POINTS = 20; # Manufacturing margin for spectral mask testPER_PASS_LIMIT = 90; # Minimum number of good packets in TX_PER tests to pass SEN_PASS_LIMIT = 90; # Minimum number of good packets in RX_SEN tests to pass PPM_MAX_LIMIT = 15; # Maximum permitted PPM, after correcting for GOLDEN_PPMPPM_MIN_LIMIT =-15; # Minimum permitted PPM, after correcting for GOLDEN_PPMTARGET_POWER_TOLERANCE_UPPER = 1; # Tolerance in dB to allow for target power control (double)TARGET_POWER_TOLERANCE_LOWER = 1.5; # Tolerance in dB to allow for target power control (double)MAX_RETEST_NUM = 3; # Maximum number of times a test is run. Set value >= 1# Calibration flags CAL_POWER = 1; # Calibrate power levels for 11a/b/g for modes supportedUSE_11g_CAL_FOR_11b = 1; # Use 11g calibration data for 11b cal.REPROGRAM_TARGET_POWER = 0; # Re-program target power. No power measurements doneDO_IQ_CAL = 0; # Perform iq_cal mismatch calibration# Use the following FIXED_GAIN setting to disable auto FIXED_GAIN algorithm for 11a and 11g mode# You can force FIXED_GAIN to the value between 0 (lowest) and 8 (highest)# If you comment out the following two lines, ART program will find the best FG setting automatically# FIXED_GAIN setting for 11b is fixed at 4 (auto or manual)CAL_FIXED_GAIN = 6; # fixed gain to use for 11a calibration measurements11g_CAL_FIXED_GAIN = 6; # fixed gain to use for 11g calibration measurements11b_CAL_FIXED_GAIN = 6; # fixed gain to use for 11b calibration measurements# Use the following default iq_cal coeffs if can't run the iq_cal for any reason. it is recommended to run the# iq_cal on each board for optimum results.I_COEFF_5G = 8; # typical i_coeff in 11a modeQ_COEFF_5G = -1; # typical q_coeff in 11a modeI_COEFF_2G = 4; # typical i_coeff in 11g modeQ_COEFF_2G = 0; # typical q_coeff in 11g mode#FTP Download specificationDO_FTP_DOWNLOAD = 0; # Set to download AP image at end of calibrationFTP_HOSTNAME = 10.10.12.206; # server to FTP fromFTP_USERNAME = mdk; # User name for FTP loginFTP_PASSWORD = atheros; # password for FTP loginFTP_REMOTE_FILE = test\freedomart.sys; # file that will be copied onto the APFTP_LOCAL_FILE = APIMG1 # Name of the file on the AP.########################################## calsetup specific to 11a mode ##########################################GOLDEN_TX_POWER = 10; # Desired output power from the GU for 11a RXSEN test (double)MAX_POWER_CAP = 18; # Cap power measurements during calibrationFORCE_PIERS = 1; # calibrate power only at channels in the FORCE_PIERS_LIST##FORCE_PIERS_LIST = 5170, 5230, 5300, 5400, 5500, 5650, 5725, 5825; # a maximum of up to 10 piers.FORCE_PIERS_LIST = 5180, 5320, 5300, 5240, 5745, 5785, 5825; # a maximum of up to 10 piers.READ_FROM_FILE = 0; # skip 11a cal. read data from a file instead.RAW_DATA_FILENAME = cal_AR5211_power.log; # read 11a data from this file# AUTO_PIERS : When FORCE_PIERS is off, set the following three parameters # to allow ART to automatically find the turning points over the# desired range.#AUTO_PIER_START = 5150; # (default 4900 if not specified)#AUTO_PIER_STOP = 5500; # (default 5850 if not specified)#AUTO_PIER_STEP = 30; # (default 70 if not specified) keep between 10-100MHz # General test flagsTEST_32KHZ_SLEEP_CRYSTAL = 1; # Test for proper functioning of the 32KHz sleep crystal# 11a mode test flags TEST_TEMP_MARGIN = 0; # Test for target power control across 0-85C at 11a test freqencies.TEST_OBW_MASK = 0; # Test occupied bandwidth mask at 11a test frequenciesTEST_SPEC_MASK = 0; # Test spectral mask at 11a test frequencies TEST_TXPER = 0; # Test Transmit Packet Error Rate at 11a test frequencies TEST_RXSEN = 0; # Test Receive Sensitivity at 11a test frequencies TEST_TURBO_MODE = 0; # Test PER and RXSEN in the turbo mode at 11a test frequencies TEST_HALF_RATE_MODE = 0; # Test PER and RXSEN in the half rate mode at 11a test frequencies TEST_TARGET_POWER = 0; # Test Target Power at 11a test frequencies TEST_THROUGHPUT = 0;# 11a, 11b and 11g Test Channel Matrices : # Rules:# 1. upto 32 test frequencies for each mode.# 2. if flags are turned on above to perform the TEMP_MARGIN_TEST, spectral mask, TXPER,# RXSEN and target power tests for 11a/b/g modes, they # will be performed at the following test frequencies based upon the# values in the PER_TEST, MASK_TEST, TGT_PWR_TEST and TEMP_MARGIN_TEST columns.# 3. OBW_TEST can be specified ONLY for 11a mode.##BEGIN_11a_TEST_CHANNEL_MATRIX # test_frequencies PER/SEN SEN LO_RATE LO_RATE TURBO HALF_RATE MASK OBW TGT_PWR TEMP_MARGIN TEST PASS# TEST TGT SEN SEN_TGT PER/SEN PER/SEN TEST TEST TEST TEST T/P THRESHOLD# UNII-1&2 (5.15-5.35GHz) test channels 5180 1 -68 0 -88 1 0 1 0 1111 1 1 28.0# 5200 1 -68 0 -88 0 0 1 0 1111 0 1 28.0# 5220 1 -68 0 -88 0 0 1 0 1111 0 1 28.0# 5240 1 -68 0 -88 0 0 1 0 1111 0 1 28.0# 5260 1 -68 0 -88 0 0 0 0 1111 1 1 28.0# 5280 1 -68 0 -88 0 0 1 0 1111 0 1 28.0# 5300 1 -68 0 -88 0 0 1 0 1111 0 1 28.0 5320 1 -68 0 -88 1 0 1 0 1111 1 1 28.0# FCC turbo (static) test channels# 5210 0 -68 0 -88 1 0 0 0 0000 0 1 28.0# 5250 0 -68 0 -88 1 0 0 0 0000 0 1 28.0# 5290 0 -68 0 -88 1 0 0 0 0000 0 1 28.0# Dynamic turbo test channels# 5200 0 -68 0 -88 1 0 0 0 0000 0 1 28.0 5240 0 -68 0 -88 1 0 0 0 0000 0 1 28.0# 5280 0 -68 0 -88 1 0 0 0 0000 0 1 28.0# 5765 0 -68 0 -88 1 0 0 0 0000 0 1 28.0# 5805 0 -68 0 -88 1 0 0 0 0000 0 1 28.0# UNII-3 & ISM band test channels 5745 1 -68 0 -88 1 0 0 0 1111 1 1 28.0# 5765 1 -68 0 -88 0 0 0 0 1111 0 1 28.0 5785 0 -68 0 -88 1 0 0 0 0000 0 1 28.0# 5805 1 -68 0 -88 0 0 0 0 1111 0 1 28.0 5825 1 -68 0 -88 1 0 0 0 1111 1 1 28.0# ETSI (5.47-5.7GHz) test channels# 5500 1 -68 0 -88 0 0 0 0 1111 0 1 28.0# 5520 1 -68 0 -88 0 0 0 0 1111 0 1 28.0# 5540 1 -68 0 -88 0 0 0 0 1111 0 1 28.0# 5560 1 -68 0 -88 0 0 0 0 1111 0 1 28.0# 5580 1 -68 0 -88 0 0 0 0 1111 0 1 28.0# 5600 1 -68 0 -88 0 0 0 0 1111 0 1 28.0# 5620 1 -68 0 -88 0 0 0 0 1111 0 1 28.0# 5640 1 -68 0 -88 0 0 0 0 1111 0 1 28.0# 5660 1 -68 0 -88 0 0 0 0 1111 0 1 28.0# 5680 1 -68 0 -88 0 0 0 0 1111 0 1 28.0# 5700 1 -68 0 -88 0 0 0 0 1111 0 1 28.0# MKK (5.15-5.25GHz) test channels# 5170 0 -68 0 -88 0 0 0 1 1111 0 1 28.0# 5190 0 -68 0 -88 0 0 0 1 1111 0 1 28.0# 5210 0 -68 0 -88 0 0 0 1 1111 0 1 28.0# 5230 0 -68 0 -88 0 0 0 1 1111 0 1 28.0# MKK (4.9-5.1GHz) test channels# 4900 0 -68 0 -88 0 0 0 1 1111 0 1 28.0# 4920 0 -68 0 -88 0 0 0 1 1111 0 1 28.0# 4940 0 -68 0 -88 0 0 0 1 1111 0 1 28.0# 4960 0 -68 0 -88 0 0 0 1 1111 0 1 28.0# 4980 0 -68 0 -88 0 0 0 1 1111 0 1 28.0# 5040 0 -68 0 -88 0 0 0 1 1111 0 1 28.0# 5060 0 -68 0 -88 0 0 0 1 1111 0 1 28.0# 5080 0 -68 0 -88 0 0 0 1 1111 0 1 28.0#END_11a_TEST_CHANNEL_MATRIX ########################################## calsetup specific to 11b mode ##########################################11b_GOLDEN_TX_POWER = 30; # Desired output power from the GU for 11b RXSEN test (double)11b_MAX_POWER_CAP = 20; # Cap power measurements during calibrationFORCE_PIERS_11b = 1; # calibrate power only at channels in the FORCE_PIERS_LIST_11bFORCE_PIERS_LIST_11b = 2417, 2442, 2462; # a maximum of up to 3 piers. 11b_READ_FROM_FILE = 0; # skip 11b cal. read data from a file instead.11b_RAW_DATA_FILENAME = cal_AR5211_power_11b.log; # read 11b data from this file # 11b mode test flags 11b_TEST_TEMP_MARGIN = 0; # Test for target power control across 0-85C at 11b test freqencies.11b_TEST_SPEC_MASK = 0; # Test spectral mask at 11b test frequencies 11b_TEST_TXPER = 0; # Test Transmit Packet Error Rate at 11b test frequencies 11b_TEST_RXSEN = 0; # Test Receive Sensitivity at 11b test frequencies 11b_TEST_TARGET_POWER = 0; # Test Target Power at 11b test frequencies 11b_TEST_THROUGHPUT = 0;#BEGIN_11b_TEST_CHANNEL_MATRIX # test_frequencies PER/SEN SEN LO_RATE LO_RATE MASK TGT_PWR TEMP_MARGIN TEST PASS# TEST TGT SEN SEN_TGT TEST TEST TEST T/P THRESHOLD# 2412 1 -85 0 -90 0 1111 0 1 7.0 2417 1 -85 0 -90 1 1111 1 1 7.0# 2422 1 -85 0 -90 0 1111 0 1 7.0# 2427 1 -85 0 -90 0 1111 0 1 7.0# 2432 1 -85 0 -90 0 1111 0 1 7.0# 2437 1 -85 0 -90 0 1111 0 1 7.0 2442 0 -85 0 -90 1 1111 1 1 7.0# 2447 1 -85 0 -90 0 1111 0 1 7.0# 2452 1 -85 0 -90 0 1111 0 1 7.0# 2457 1 -85 0 -90 0 1111 0 1 7.0 2462 1 -85 0 -90 1 1111 1 1 7.0# 2467 1 -85 0 -90 0 1111 0 1 7.0# 2472 1 -85 0 -90 0 1111 0 1 7.0# 2484 1 -85 0 -90 0 1111 0 1 7.0#END_11b_TEST_CHANNEL_MATRIX ########################################## calsetup specific to 11g mode ##########################################11g_GOLDEN_TX_POWER = 10; # Desired output power from the GU for 11g RXSEN test (double)11g_MAX_POWER_CAP = 20; # Cap power measurements during calibrationFORCE_PIERS_11g = 1; # calibrate power only at channels in the FORCE_PIERS_LIST#FORCE_PIERS_LIST_11g = 2412 2442 2462 ; # a maximum of up to 3 piers.FORCE_PIERS_LIST_11g = 2412 ; # a maximum of up to 3 piers.11g_READ_FROM_FILE = 0; # skip 11g cal. read data from a file instead.11g_RAW_DATA_FILENAME = cal_AR5211_power_11g.log; # read 11g data from this file # 11g mode test flags 11g_TEST_TEMP_MARGIN = 0; # Test for target power control across 0-85C at 11g test freqencies.11g_TEST_SPEC_MASK = 1; # Test spectral mask at 11g test frequencies 11g_TEST_TXPER = 1; # Test Transmit Packet Error Rate at 11g test frequencies 11g_TEST_RXSEN = 1; # Test Receive Sensitivity at 11g test frequencies 11g_TEST_TARGET_POWER = 1; # Test Target Power at 11g test frequencies 11g_TEST_TURBO_MODE = 0; # Test PER and RXSEN in the turbo mode at 11g test frequencies 11g_TEST_DATA_INTEGRITY = 0; # Test memory by performing data comparison for long packets 11g_TEST_THROUGHPUT = 0;#BEGIN_11g_TEST_CHANNEL_MATRIX # test_frequencies PER/SEN SEN LO_RATE LO_RATE TURBO MASK TGT_PWR TEMP_MARGIN TEST PASS# TEST TGT SEN SEN_TGT PER/SEN TEST TEST TEST T/P THRESHOLD 2412 1 -68 0 -88 0 0 1111 0 1 28.0# 2417 1 -68 0 -88 1 1 1111 1 1 28.0# 2422 1 -68 0 -88 0 0 1111 0 1 28.0# 2427 1 -68 0 -88 0 0 1111 0 1 28.0# 2432 1 -68 0 -88 0 0 1111 0 1 28.0# 2437 1 -68 0 -88 0 1 1111 0 1 28.0 # 2442 0 -68 0 -88 1 1 1111 1 1 28.0# 2447 1 -68 0 -88 0 0 1111 0 1 28.0# 2452 1 -68 0 -88 0 0 1111 0 1 28.0# 2457 1 -68 0 -88 0 0 1111 0 1 28.0 # 2462 1 -68 0 -88 1 1 1111 1 1 28.0# 2467 1 -68 0 -88 0 0 1111 0 1 28.0# 2472 1 -68 0 -88 0 0 1111 0 1 28.0# 2484 1 -68 0 -88 0 0 1111 0 1 28.0#END_11g_TEST_CHANNEL_MATRIX
?? 快捷鍵說明
復制代碼
Ctrl + C
搜索代碼
Ctrl + F
全屏模式
F11
切換主題
Ctrl + Shift + D
顯示快捷鍵
?
增大字號
Ctrl + =
減小字號
Ctrl + -