THIS TEXT DESCRIPTION IS GENERATED BY THE TOOL. DO NOT MODIFY IT.
=============================================================================
Module "PWM8Di" (bean PWM)
- PWM8Di_SetRatio16 -This method sets a new duty-cycle ratio. Ratio is expressed as a 16-bit unsigned integer number. 0 -
FFFF value is proportional to ratio 0 - 100%. Note: Calculated duty depends on the timer possibilities and on
the selected period.
- PWM8Di_SetDutyUS -This method sets the new duty value of the output signal. The duty is expressed in microseconds as a
16-bit unsigned integer number.
- PWM8Di_SetDutyMS -This method sets the new duty value of the output signal. The duty is expressed in milliseconds as a
16-bit unsigned integer number.
Module "TI1" (bean TimerInt)
- TI1_Enable -Enables the bean - it starts the timer. Events may be generated ("DisableEvent"/"EnableEvent").
- TI1_Disable -Disables the bean - it stops the timer. No events will be generated.
Module "AD2" (bean ADC)
- AD2_Enable -Enables A/D converter bean. <Events> may be generated (<DisableEvent>/<EnableEvent>). If possible, this method
switches on A/D converter device, voltage reference, etc.
- AD2_Disable -Disables A/D converter bean. No <events> will be generated. If possible, this method switches off A/D
converter device, voltage reference, etc.
- AD2_Start -This method starts continuous conversion on all channels that are set in the bean inspector. When each
measurement on all channels has finished the <OnEnd > event may be invoked. This method is not available if the
<interrupt service> is disabled and the device doesn't support the continuous mode. Note: If time of
measurement is too short and the instruction clock is too slow then the conversion complete interrupt and its
handler may cause a system overflow.
- AD2_Stop -This method stops the continuous measurement, which had been started by <Start> method, or this method disables
a trigger mode which has been enabled by <EnableInt(Chan)Trigger> or <EnableExt(Chan)Trigger> method (if these
are supported by HW). This method is available if at least one of <Start>, <EnableInt(Chan)Trigger> or
<EnableExt(Chan)Trigger> methods is supported by A/D converter device and it is enabled to be generated.
- AD2_Measure -This method performs one measurement on all channels that are set in the bean inspector. (Note: If the
<number of conversions> is more than one the conversion of A/D channels is performed specified number of times.)
- AD2_GetValue8 -This method returns the last measured values of all channels justified to the left. Compared with
<GetValue> method this method returns more accurate result if the <number of conversions> is greater than 1 and
<AD resolution> is less than 8 bits. In addition, the user code dependency on <AD resolution> is eliminated.
- AD2_GetChanValue8 -This method returns the last measured value of required channel justified to the left. Compared with
<GetChanValue> method this method returns more accurate result if the <number of conversions> is greater than 1
and <AD resolution> is less than 8 bits. In addition, the user code dependency on <AD resolution> is eliminated.
Module "AD3" (bean ADC)
- AD3_Enable -Enables A/D converter bean. <Events> may be generated (<DisableEvent>/<EnableEvent>). If possible, this method
switches on A/D converter device, voltage reference, etc.
- AD3_Disable -Disables A/D converter bean. No <events> will be generated. If possible, this method switches off A/D
converter device, voltage reference, etc.
- AD3_Start -This method starts continuous conversion on all channels that are set in the bean inspector. When each
measurement on all channels has finished the <OnEnd > event may be invoked. This method is not available if the
<interrupt service> is disabled and the device doesn't support the continuous mode. Note: If time of
measurement is too short and the instruction clock is too slow then the conversion complete interrupt and its
handler may cause a system overflow.
- AD3_Stop -This method stops the continuous measurement, which had been started by <Start> method, or this method disables
a trigger mode which has been enabled by <EnableInt(Chan)Trigger> or <EnableExt(Chan)Trigger> method (if these
are supported by HW). This method is available if at least one of <Start>, <EnableInt(Chan)Trigger> or
<EnableExt(Chan)Trigger> methods is supported by A/D converter device and it is enabled to be generated.
- AD3_Measure -This method performs one measurement on all channels that are set in the bean inspector. (Note: If the
<number of conversions> is more than one the conversion of A/D channels is performed specified number of times.)
- AD3_GetValue8 -This method returns the last measured values of all channels justified to the left. Compared with
<GetValue> method this method returns more accurate result if the <number of conversions> is greater than 1 and
<AD resolution> is less than 8 bits. In addition, the user code dependency on <AD resolution> is eliminated.
- AD3_GetChanValue8 -This method returns the last measured value of required channel justified to the left. Compared with
<GetChanValue> method this method returns more accurate result if the <number of conversions> is greater than 1
and <AD resolution> is less than 8 bits. In addition, the user code dependency on <AD resolution> is eliminated.
Module "PWM8h" (bean PWM)
- PWM8h_SetRatio16 -This method sets a new duty-cycle ratio. Ratio is expressed as a 16-bit unsigned integer number. 0 -
FFFF value is proportional to ratio 0 - 100%. Note: Calculated duty depends on the timer possibilities and on
the selected period.
- PWM8h_SetDutyUS -This method sets the new duty value of the output signal. The duty is expressed in microseconds as a
16-bit unsigned integer number.
- PWM8h_SetDutyMS -This method sets the new duty value of the output signal. The duty is expressed in milliseconds as a
16-bit unsigned integer number.
Module "PWMd" (bean PWM)
- PWMd_SetRatio16 -This method sets a new duty-cycle ratio. Ratio is expressed as a 16-bit unsigned integer number. 0 - FFFF
value is proportional to ratio 0 - 100%. Note: Calculated duty depends on the timer possibilities and on the
selected period.
- PWMd_SetDutyUS -This method sets the new duty value of the output signal. The duty is expressed in microseconds as a
16-bit unsigned integer number.
- PWMd_SetDutyMS -This method sets the new duty value of the output signal. The duty is expressed in milliseconds as a
16-bit unsigned integer number.
Module "IEE1" (bean IntEEPROM)
- IEE1_SetByte -Method writes a given byte to a specified address in EEPROM.
- IEE1_GetByte -Method reads a byte from a specified EEPROM address
- IEE1_SetWord -Method writes a given word to the specified address in EEPROM.
- IEE1_GetWord -Method reads a word from the specified EEPROM address
Module "TI2" (bean TimerInt)
- TI2_Enable -Enables the bean - it starts the timer. Events may be generated ("DisableEvent"/"EnableEvent").
- TI2_Disable -Disables the bean - it stops the timer. No events will be generated.
Module "Cpu" (bean MC9S12DG128_112)
- Cpu_EnableInt -Enable maskable interrupts
- Cpu_DisableInt -Disable maskable interrupts
- Cpu_SetWaitMode -Set low power mode - Wait mode. For more information about the wait mode see documentation of this CPU.
Release from Wait mode: Reset or interrupt
- Cpu_SetStopMode -Set low power mode - Stop mode. For more information about the stop mode see documentation of this CPU.
===================================================================================