?? calsetup.txt
字號:
# calsetup file updated for eeprom version 3.3, ART version 2.4
# General Info
COUNTRY_OR_DOMAIN_FLAG = 0; # 1 indicates the code is a country code. 0=>regulatory domain code
WORLD_WIDE_ROAMING_FLAG = 0; # 1 indicates a single SKU covering worldwide roaming
COUNTRY_OR_DOMAIN_CODE = 0x000; # 12-bit country or domain code for intended region-of-use (hex)
SUB_VENDOR_ID = 0x168C; # SubVendor ID in hex
MACID_FILENAME = L:\ART\macid.txt; # central macID file
CUSTOMER_DEBUG = 0; # not to be turned on in normal operation.
SHOW_TIMING_REPORT = 0; # show time taken by various tests
ATHEROS_LOGGING_SCHEME = 0; # Enable the Atheros specific label scheme
# Instrumentation Info
USE_INSTRUMENTS = 1; # Select whether Instruments are Connected
PM_MODEL = 2; # 1 => HP 436A, 2 => Agilent E4416A, 3 => 4531
PM_GPIB_ADDR = 14; # Power meter GPIB Address
SA_GPIB_ADDR = 18; # Spectrum analyzer GPIB Address
ATT_GPIB_ADDR = 4; # Attenuator GPIB Address
GOLDEN_IP_ADDR = 10.10.12.103; # IP addr of the golden machine
#GOLDEN_IP_ADDR = .; # Use . if both DUT and GU are control by same machine
# Calibration Setup Info
CASE_TEMPERATURE = 45; # Case temperature of the AR5111 on the DUT during calibration (int)
GOLDEN_PPM = -3; # Measured PPM of golden device (int)
ATTEN_DUT_SA = 13.5; # Attenuation at 5.5GHz between DUT and spectrum analyzer (double)
ATTEN_FIXED_DUT_GOLDEN = 44.4; # Fixed attenuation at 5.5GHz between DUT and GOLDEN (double)
ATTEN_DUT_PM = 12.8; # Attenuation at 5.5GHz between DUT and power meter (double)
11b_ATTEN_DUT_SA = 12.5; # Attenuation at 2.5GHz between DUT and spectrum analyzer (double)
11b_ATTEN_FIXED_DUT_GOLDEN = 41.8; # Fixed attenuation at 2.5GHz between DUT and GOLDEN (double)
11b_ATTEN_DUT_PM = 11.5; # Attenuation at 2.5GHz between DUT and power meter (double)
# Test Margins
NUM_MASK_FAIL_POINTS = 20; # Manufacturing margin for spectral mask test
PER_PASS_LIMIT = 90; # Minimum number of good packets in TX_PER tests to pass
SEN_PASS_LIMIT = 90; # Minimum number of good packets in RX_SEN tests to pass
PPM_MAX_LIMIT = 15; # Maximum permitted PPM, after correcting for GOLDEN_PPM
PPM_MIN_LIMIT =-15; # Minimum permitted PPM, after correcting for GOLDEN_PPM
TARGET_POWER_TOLERANCE_UPPER = 1; # Tolerance in dB to allow for target power control (double)
TARGET_POWER_TOLERANCE_LOWER = 1.5; # Tolerance in dB to allow for target power control (double)
MAX_RETEST_NUM = 3; # Maximum number of times a test is run. Set value >= 1
# Calibration flags
CAL_POWER = 1; # Calibrate power levels for 11a/b/g for modes supported
USE_11g_CAL_FOR_11b = 1; # Use 11g calibration data for 11b cal.
REPROGRAM_TARGET_POWER = 0; # Re-program target power. No power measurements done
DO_IQ_CAL = 1; # Perform iq_cal mismatch calibration
# Use the following FIXED_GAIN setting to disable auto FIXED_GAIN algorithm for 11a and 11g mode
# You can force FIXED_GAIN to the value between 0 (lowest) and 8 (highest)
# If you comment out the following two lines, ART program will find the best FG setting automatically
# FIXED_GAIN setting for 11b is fixed at 4 (auto or manual)
CAL_FIXED_GAIN = 6; # fixed gain to use for 11a calibration measurements
11g_CAL_FIXED_GAIN = 6; # fixed gain to use for 11g calibration measurements
11b_CAL_FIXED_GAIN = 6; # fixed gain to use for 11b calibration measurements
# Use the following default iq_cal coeffs if can't run the iq_cal for any reason. it is recommended to run the
# iq_cal on each board for optimum results.
I_COEFF_5G = 8; # typical i_coeff in 11a mode
Q_COEFF_5G = -1; # typical q_coeff in 11a mode
I_COEFF_2G = 4; # typical i_coeff in 11g mode
Q_COEFF_2G = 0; # typical q_coeff in 11g mode
#FTP Download specification
DO_FTP_DOWNLOAD = 0; # Set to download AP image at end of calibration
FTP_HOSTNAME = 10.10.12.206; # server to FTP from
FTP_USERNAME = mdk; # User name for FTP login
FTP_PASSWORD = atheros; # password for FTP login
FTP_REMOTE_FILE = test\freedomart.sys; # file that will be copied onto the AP
FTP_LOCAL_FILE = APIMG1 # Name of the file on the AP.
#######################################
### calsetup specific to 11a mode ###
#######################################
GOLDEN_TX_POWER = 10; # Desired output power from the GU for 11a RXSEN test (double)
MAX_POWER_CAP = 20; # Cap power measurements during calibration
FORCE_PIERS = 1; # calibrate power only at channels in the FORCE_PIERS_LIST
FORCE_PIERS_LIST = 5170, 5230, 5300, 5400, 5500, 5650, 5725, 5825; # a maximum of up to 10 piers.
READ_FROM_FILE = 0; # skip 11a cal. read data from a file instead.
RAW_DATA_FILENAME = cal_AR5211_power.log; # read 11a data from this file
# AUTO_PIERS : When FORCE_PIERS is off, set the following three parameters
# to allow ART to automatically find the turning points over the
# desired range.
#AUTO_PIER_START = 5150; # (default 4900 if not specified)
#AUTO_PIER_STOP = 5500; # (default 5850 if not specified)
#AUTO_PIER_STEP = 30; # (default 70 if not specified) keep between 10-100MHz
# General test flags
TEST_32KHZ_SLEEP_CRYSTAL = 1; # Test for proper functioning of the 32KHz sleep crystal
# 11a mode test flags
TEST_TEMP_MARGIN = 0; # Test for target power control across 0-85C at 11a test freqencies.
TEST_OBW_MASK = 1; # Test occupied bandwidth mask at 11a test frequencies
TEST_SPEC_MASK = 1; # Test spectral mask at 11a test frequencies
TEST_TXPER = 1; # Test Transmit Packet Error Rate at 11a test frequencies
TEST_RXSEN = 1; # Test Receive Sensitivity at 11a test frequencies
TEST_TURBO_MODE = 1; # Test PER and RXSEN in the turbo mode at 11a test frequencies
TEST_HALF_RATE_MODE = 0; # Test PER and RXSEN in the half rate mode at 11a test frequencies
TEST_TARGET_POWER = 1; # Test Target Power at 11a test frequencies
TEST_THROUGHPUT = 0;
# 11a, 11b and 11g Test Channel Matrices :
# Rules:
# 1. upto 32 test frequencies for each mode.
# 2. if flags are turned on above to perform the TEMP_MARGIN_TEST, spectral mask, TXPER,
# RXSEN and target power tests for 11a/b/g modes, they
# will be performed at the following test frequencies based upon the
# values in the PER_TEST, MASK_TEST, TGT_PWR_TEST and TEMP_MARGIN_TEST columns.
# 3. OBW_TEST can be specified ONLY for 11a mode.
#
#BEGIN_11a_TEST_CHANNEL_MATRIX
# test_frequencies PER/SEN SEN LO_RATE LO_RATE TURBO HALF_RATE MASK OBW TGT_PWR TEMP_MARGIN TEST PASS
# TEST TGT SEN SEN_TGT PER/SEN PER/SEN TEST TEST TEST TEST T/P THRESHOLD
# UNII-1&2 (5.15-5.35GHz) test channels
5180 1 -68 0 -88 0 0 1 0 1111 1 1 27.0
# 5200 1 -68 0 -88 0 0 1 0 1111 0 1 27.0
# 5220 1 -68 0 -88 0 0 1 0 1111 0 1 27.0
# 5240 1 -68 0 -88 0 0 1 0 1111 0 1 27.0
5260 1 -68 0 -88 0 0 0 0 1111 1 1 27.0
# 5280 1 -68 0 -88 0 0 1 0 1111 0 1 27.0
# 5300 1 -68 0 -88 0 0 1 0 1111 0 1 27.0
5320 1 -68 0 -88 0 0 1 0 1111 1 1 27.0
# FCC turbo (static) test channels
# 5210 0 -68 0 -88 1 0 0 0 0000 0 1 27.0
# 5250 0 -68 0 -88 1 0 0 0 0000 0 1 27.0
# 5290 0 -68 0 -88 1 0 0 0 0000 0 1 27.0
# Dynamic turbo test channels
# 5200 0 -68 0 -88 1 0 0 0 0000 0 1 27.0
5240 0 -68 0 -88 1 0 0 0 0000 0 1 27.0
# 5280 0 -68 0 -88 1 0 0 0 0000 0 1 27.0
# 5765 0 -68 0 -88 1 0 0 0 0000 0 1 27.0
# 5805 0 -68 0 -88 1 0 0 0 0000 0 1 27.0
# UNII-3 & ISM band test channels
5745 1 -68 0 -88 0 0 0 0 1111 1 1 27.0
# 5765 1 -68 0 -88 0 0 0 0 1111 0 1 27.0
5785 0 -68 0 -88 1 0 0 0 0000 0 1 27.0
# 5805 1 -68 0 -88 0 0 0 0 1111 0 1 27.0
5825 1 -68 0 -88 0 0 0 0 1111 1 1 27.0
# ETSI (5.47-5.7GHz) test channels
# 5500 1 -68 0 -88 0 0 0 0 1111 0 1 27.0
# 5520 1 -68 0 -88 0 0 0 0 1111 0 1 27.0
# 5540 1 -68 0 -88 0 0 0 0 1111 0 1 27.0
# 5560 1 -68 0 -88 0 0 0 0 1111 0 1 27.0
# 5580 1 -68 0 -88 0 0 0 0 1111 0 1 27.0
# 5600 1 -68 0 -88 0 0 0 0 1111 0 1 27.0
# 5620 1 -68 0 -88 0 0 0 0 1111 0 1 27.0
# 5640 1 -68 0 -88 0 0 0 0 1111 0 1 27.0
# 5660 1 -68 0 -88 0 0 0 0 1111 0 1 27.0
# 5680 1 -68 0 -88 0 0 0 0 1111 0 1 27.0
# 5700 1 -68 0 -88 0 0 0 0 1111 0 1 27.0
# MKK (5.15-5.25GHz) test channels
# 5170 0 -68 0 -88 0 0 0 1 1111 0 1 27.0
# 5190 0 -68 0 -88 0 0 0 1 1111 0 1 27.0
# 5210 0 -68 0 -88 0 0 0 1 1111 0 1 27.0
# 5230 0 -68 0 -88 0 0 0 1 1111 0 1 27.0
# MKK (4.9-5.1GHz) test channels
# 4900 0 -68 0 -88 0 0 0 1 1111 0 1 27.0
# 4920 0 -68 0 -88 0 0 0 1 1111 0 1 27.0
# 4940 0 -68 0 -88 0 0 0 1 1111 0 1 27.0
# 4960 0 -68 0 -88 0 0 0 1 1111 0 1 27.0
# 4980 0 -68 0 -88 0 0 0 1 1111 0 1 27.0
# 5040 0 -68 0 -88 0 0 0 1 1111 0 1 27.0
# 5060 0 -68 0 -88 0 0 0 1 1111 0 1 27.0
# 5080 0 -68 0 -88 0 0 0 1 1111 0 1 27.0
#END_11a_TEST_CHANNEL_MATRIX
#######################################
### calsetup specific to 11b mode ###
#######################################
11b_GOLDEN_TX_POWER = 18; # Desired output power from the GU for 11b RXSEN test (double)
11b_MAX_POWER_CAP = 20; # Cap power measurements during calibration
FORCE_PIERS_11b = 1; # calibrate power only at channels in the FORCE_PIERS_LIST_11b
FORCE_PIERS_LIST_11b = 2412, 2472, 2484; # a maximum of up to 3 piers.
11b_READ_FROM_FILE = 0; # skip 11b cal. read data from a file instead.
11b_RAW_DATA_FILENAME = cal_AR5211_power_11b.log; # read 11b data from this file
# 11b mode test flags
11b_TEST_TEMP_MARGIN = 0; # Test for target power control across 0-85C at 11b test freqencies.
11b_TEST_SPEC_MASK = 1; # Test spectral mask at 11b test frequencies
11b_TEST_TXPER = 1; # Test Transmit Packet Error Rate at 11b test frequencies
11b_TEST_RXSEN = 1; # Test Receive Sensitivity at 11b test frequencies
11b_TEST_TARGET_POWER = 1; # Test Target Power at 11b test frequencies
11b_TEST_THROUGHPUT = 0;
#BEGIN_11b_TEST_CHANNEL_MATRIX
# test_frequencies PER/SEN SEN LO_RATE LO_RATE MASK TGT_PWR TEMP_MARGIN TEST PASS
# TEST TGT SEN SEN_TGT TEST TEST TEST T/P THRESHOLD
2412 1 -85 0 -90 0 1111 0 1 6.0
# 2417 1 -85 0 -90 0 1111 0 1 6.0
# 2422 1 -85 0 -90 0 1111 0 1 6.0
# 2427 1 -85 0 -90 0 1111 0 1 6.0
# 2432 1 -85 0 -90 0 1111 0 1 6.0
2437 1 -85 0 -90 0 1111 0 1 6.0
2442 0 -85 0 -90 1 0000 0 0 6.0
# 2447 1 -85 0 -90 0 1111 0 1 6.0
# 2452 1 -85 0 -90 0 1111 0 1 6.0
# 2457 1 -85 0 -90 0 1111 0 1 6.0
# 2462 1 -85 0 -90 0 1111 0 1 6.0
# 2467 1 -85 0 -90 0 1111 0 1 6.0
# 2472 1 -85 0 -90 0 1111 0 1 6.0
2484 1 -85 0 -90 0 1111 0 1 6.0
#END_11b_TEST_CHANNEL_MATRIX
#######################################
### calsetup specific to 11g mode ###
#######################################
11g_GOLDEN_TX_POWER = 10; # Desired output power from the GU for 11g RXSEN test (double)
11g_MAX_POWER_CAP = 20; # Cap power measurements during calibration
FORCE_PIERS_11g = 1; # calibrate power only at channels in the FORCE_PIERS_LIST
FORCE_PIERS_LIST_11g = 2442; # a maximum of up to 3 piers.
11g_READ_FROM_FILE = 0; # skip 11g cal. read data from a file instead.
11g_RAW_DATA_FILENAME = cal_AR5211_power_11g.log; # read 11g data from this file
# 11g mode test flags
11g_TEST_TEMP_MARGIN = 0; # Test for target power control across 0-85C at 11g test freqencies.
11g_TEST_SPEC_MASK = 1; # Test spectral mask at 11g test frequencies
11g_TEST_TXPER = 1; # Test Transmit Packet Error Rate at 11g test frequencies
11g_TEST_RXSEN = 1; # Test Receive Sensitivity at 11g test frequencies
11g_TEST_TARGET_POWER = 1; # Test Target Power at 11g test frequencies
11g_TEST_TURBO_MODE = 0; # Test PER and RXSEN in the turbo mode at 11g test frequencies
11g_TEST_DATA_INTEGRITY = 0; # Test memory by performing data comparison for long packets
11g_TEST_THROUGHPUT = 0;
#BEGIN_11g_TEST_CHANNEL_MATRIX
# test_frequencies PER/SEN SEN LO_RATE LO_RATE TURBO MASK TGT_PWR TEMP_MARGIN TEST PASS
# TEST TGT SEN SEN_TGT PER/SEN TEST TEST TEST T/P THRESHOLD
2412 1 -68 0 -88 0 0 1111 0 1 28.0
# 2417 1 -68 0 -88 0 0 1111 0 1 28.0
# 2422 1 -68 0 -88 0 0 1111 0 1 28.0
# 2427 1 -68 0 -88 0 0 1111 0 1 28.0
# 2432 1 -68 0 -88 0 0 1111 0 1 28.0
2437 1 -68 0 -88 0 1 1111 0 1 28.0
# 2442 0 -68 0 -88 0 0 1111 0 0 28.0
# 2447 1 -68 0 -88 0 0 1111 0 1 28.0
# 2452 1 -68 0 -88 0 0 1111 0 1 28.0
# 2457 1 -68 0 -88 0 0 1111 0 1 28.0
# 2462 1 -68 0 -88 0 0 1111 0 1 28.0
# 2467 1 -68 0 -88 0 0 1111 0 1 28.0
# 2472 1 -68 0 -88 0 0 1111 0 1 28.0
2484 1 -68 0 -88 0 0 1111 0 1 28.0
#END_11g_TEST_CHANNEL_MATRIX