<P class=p9> 分程控制的第三種使用方法是可擴大調節閥的可調范圍。有一個實際例子,某個工藝裝置要求通過調節閥計算最大流量Q<SUB><FONT
face="Times New Roman, Times, serif">max</FONT></SUB>=100m<SUP><FONT
face="Times New Roman, Times, serif">3</FONT></SUP>/h,而最小流量Q<SUB><FONT
face="Times New Roman, Times, serif">min</FONT></SUB>=2m<SUP><FONT
face="Times New Roman, Times, serif">3</FONT></SUP>/h,系統總壓降比S值為0.7。很顯然,如調節閥的固有可調比Ro為30的話,采用一個閥門是難以滿足工藝提出的要求。
</P>
<TABLE class=p9 cellSpacing=0 cellPadding=0 width="100%" border=0>
<TBODY>
<TR>
<TD vAlign=top width="58%">
<P class=p9> 因為<IMG height=35 src="part18.files/shi4.jpg" width=29
align=absMiddle> = <IMG height=28 src="part18.files/shi26.jpg" width=22
align=absMiddle> =50</P>
<P class=p9> 而R = Ro<IMG height=18 src="part18.files/shi9.jpg" width=18
align=absMiddle> = 30<IMG height=18 src="part18.files/shi27.jpg" width=29
align=absMiddle> = 25 < 50。 </P>
<P
class=p9> 這時,可選用分程控制系統,采用大小兩個調節閥,如圖28所示,以并聯連接方式。兩個閥門皆為氣開式。當工藝要求小流量,控</P></TD>
<TD vAlign=top width="42%">
<DIV align=center><IMG height=120 src="part18.files/tu28.jpg"
width=233></DIV></TD></TR></TBODY></TABLE><SPAN
class=p9>制器采用小閥控制,其通過的最大流量Q<SUB>小<FONT
face="Times New Roman, Times, serif">max</FONT></SUB>=4m<SUP><FONT
face="Times New Roman, Times, serif">3</FONT></SUP>/h,控制器的輸出信號為4-12mA。當工藝要求用大流量控制時,可采用大閥控制(Q<SUB>大<FONT
face="Times New Roman, Times, serif">max</FONT></SUB>=100m<SUP><FONT
face="Times New Roman, Times, serif">3</FONT></SUP>/h),則就能滿足工藝要求。因為這時系統的可調比為:</SPAN>
<P><SPAN class=p9> R= <IMG height=30 src="part18.files/shi28.jpg" width=87
align=absMiddle> = 653 > 50</SPAN></P>
<P><SPAN class=p9> 可調比提高了 <IMG height=29 src="part18.files/shi29.jpg" width=27
align=absMiddle> = 26倍。要注意的是大閥在關閉時,內泄漏量很小,不然的話,大閥未動作,而其內漏過去的量已起過小閥的最大量,而小閥失去作用。
</SPAN></P>
<TABLE height=20 cellSpacing=0 cellPadding=0 width=570 border=0>
<TBODY>
<TR>
<TD vAlign=center width=91>
<DIV align=center><A
href="http://www.imeter.com.cn/science/science/science_tech_right18.htm#head"><FONT
class=p9 color=#0000cc>返回頁首</FONT></A></DIV></TD>
<TD vAlign=center width=91>
<DIV align=center><A
href="http://www.imeter.com.cn/science/science/science_tech_right17.htm"><FONT
class=p9 color=#0000cc>上一頁</FONT></A></DIV></TD>
<TD width=91>
<DIV align=center><A
href="http://www.imeter.com.cn/science/science/science_tech_right19.htm"><FONT
class=p9 color=#0000cc>下一頁</FONT></A></DIV></TD>
<TD colSpan=2>
<DIV align=right><FONT class=p9
size=2></FONT></DIV></TD></TR></TBODY></TABLE><FONT class=p9>
<HR width="100%" noShade>
<DIV align=center>
<P><BR></P>
<P><A href="http://www.imeter.com.cn/science/science/science_tech_right.htm"
target=_self><FONT color=#000099 size=3>回到標題</FONT></A> </P></DIV></FONT><FONT
class=p9>
<P align=left></P></FONT></BODY></HTML>
?? 快捷鍵說明
復制代碼
Ctrl + C
搜索代碼
Ctrl + F
全屏模式
F11
切換主題
Ctrl + Shift + D
顯示快捷鍵
?
增大字號
Ctrl + =
減小字號
Ctrl + -