?? rfc2737.txt
字號:
entPhysicalAlias OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..32)) MAX-ACCESS read-write STATUS current DESCRIPTION "This object is an 'alias' name for the physical entity as specified by a network manager, and provides a non-volatile 'handle' for the physical entity. On the first instantiation of an physical entity, the value of entPhysicalAlias associated with that entity is set to the zero-length string. However, agent may set the value to a locally unique default value, instead of a zero-length string. If write access is implemented for an instance of entPhysicalAlias, and a value is written into the instance, the agent must retain the supplied value in the entPhysicalAlias instance associated with the same physical entity for as long as that entity remains instantiated. This includes instantiations across all re- initializations/reboots of the network management system,McCloghrie & Bierman Standards Track [Page 23]RFC 2737 Entity MIB (Version 2) December 1999 including those which result in a change of the physical entity's entPhysicalIndex value." ::= { entPhysicalEntry 14 }entPhysicalAssetID OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..32)) MAX-ACCESS read-write STATUS current DESCRIPTION "This object is a user-assigned asset tracking identifier for the physical entity as specified by a network manager, and provides non-volatile storage of this information. On the first instantiation of an physical entity, the value of entPhysicalAssetID associated with that entity is set to the zero-length string. Not every physical component will have a asset tracking identifier, or even need one. Physical entities for which the associated value of the entPhysicalIsFRU object is equal to 'false(2)' (e.g., the repeater ports within a repeater module), do not need their own unique asset tracking identifier. An agent does not have to provide write access for such entities, and may instead return a zero-length string. If write access is implemented for an instance of entPhysicalAssetID, and a value is written into the instance, the agent must retain the supplied value in the entPhysicalAssetID instance associated with the same physical entity for as long as that entity remains instantiated. This includes instantiations across all re- initializations/reboots of the network management system, including those which result in a change of the physical entity's entPhysicalIndex value. If no asset tracking information is associated with the physical component, then this object will contain a zero- length string." ::= { entPhysicalEntry 15 }entPhysicalIsFRU OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates whether or not this physical entity is considered a 'field replaceable unit' by the vendor. IfMcCloghrie & Bierman Standards Track [Page 24]RFC 2737 Entity MIB (Version 2) December 1999 this object contains the value 'true(1)' then this entPhysicalEntry identifies a field replaceable unit. For all entPhysicalEntries which represent components that are permanently contained within a field replaceable unit, the value 'false(2)' should be returned for this object." ::= { entPhysicalEntry 16 }-- The Logical Entity TableentLogicalTable OBJECT-TYPE SYNTAX SEQUENCE OF EntLogicalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains one row per logical entity. For agents which implement more than one naming scope, at least one entry must exist. Agents which instantiate all MIB objects within a single naming scope are not required to implement this table." ::= { entityLogical 1 }entLogicalEntry OBJECT-TYPE SYNTAX EntLogicalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information about a particular logical entity. Entities may be managed by this agent or other SNMP agents (possibly) in the same chassis." INDEX { entLogicalIndex } ::= { entLogicalTable 1 }EntLogicalEntry ::= SEQUENCE { entLogicalIndex INTEGER, entLogicalDescr SnmpAdminString, entLogicalType AutonomousType, entLogicalCommunity OCTET STRING, entLogicalTAddress TAddress, entLogicalTDomain TDomain, entLogicalContextEngineID SnmpEngineIdOrNone, entLogicalContextName SnmpAdminString}entLogicalIndex OBJECT-TYPE SYNTAX INTEGER (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTIONMcCloghrie & Bierman Standards Track [Page 25]RFC 2737 Entity MIB (Version 2) December 1999 "The value of this object uniquely identifies the logical entity. The value should be a small positive integer; index values for different logical entities are are not necessarily contiguous." ::= { entLogicalEntry 1 }entLogicalDescr OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "A textual description of the logical entity. This object should contain a string which identifies the manufacturer's name for the logical entity, and should be set to a distinct value for each version of the logical entity. " ::= { entLogicalEntry 2 }entLogicalType OBJECT-TYPE SYNTAX AutonomousType MAX-ACCESS read-only STATUS current DESCRIPTION "An indication of the type of logical entity. This will typically be the OBJECT IDENTIFIER name of the node in the SMI's naming hierarchy which represents the major MIB module, or the majority of the MIB modules, supported by the logical entity. For example: a logical entity of a regular host/router -> mib-2 a logical entity of a 802.1d bridge -> dot1dBridge a logical entity of a 802.3 repeater -> snmpDot3RptrMgmt If an appropriate node in the SMI's naming hierarchy cannot be identified, the value 'mib-2' should be used." ::= { entLogicalEntry 3 }entLogicalCommunity OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "An SNMPv1 or SNMPv2C community-string which can be used to access detailed management information for this logical entity. The agent should allow read access with this community string (to an appropriate subset of all managed objects) and may also return a community string based on the privileges of the request used to read this object. Note that an agent may return a community string with read-only privileges, even if this object is accessed with a read- write community string. However, the agent must take careMcCloghrie & Bierman Standards Track [Page 26]RFC 2737 Entity MIB (Version 2) December 1999 not to return a community string which allows more privileges than the community string used to access this object. A compliant SNMP agent may wish to conserve naming scopes by representing multiple logical entities in a single 'default' naming scope. This is possible when the logical entities represented by the same value of entLogicalCommunity have no object instances in common. For example, 'bridge1' and 'repeater1' may be part of the main naming scope, but at least one additional community string is needed to represent 'bridge2' and 'repeater2'. Logical entities 'bridge1' and 'repeater1' would be represented by sysOREntries associated with the 'default' naming scope. For agents not accessible via SNMPv1 or SNMPv2C, the value of this object is the empty string. This object may also contain an empty string if a community string has not yet been assigned by the agent, or no community string with suitable access rights can be returned for a particular SNMP request. Note that this object is deprecated. Agents which implement SNMPv3 access should use the entLogicalContextEngineID and entLogicalContextName objects to identify the context associated with each logical entity. SNMPv3 agents may return a zero-length string for this object, or may continue to return a community string (e.g., tri-lingual agent support)." ::= { entLogicalEntry 4 }entLogicalTAddress OBJECT-TYPE SYNTAX TAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The transport service address by which the logical entity receives network management traffic, formatted according to the corresponding value of entLogicalTDomain. For snmpUDPDomain, a TAddress is 6 octets long, the initial 4 octets containing the IP-address in network-byte order and the last 2 containing the UDP port in network-byte order. Consult 'Transport Mappings for Version 2 of the Simple Network Management Protocol' (RFC 1906 [RFC1906]) for further information on snmpUDPDomain."McCloghrie & Bierman Standards Track [Page 27]RFC 2737 Entity MIB (Version 2) December 1999 ::= { entLogicalEntry 5 }entLogicalTDomain OBJECT-TYPE SYNTAX TDomain MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the kind of transport service by which the logical entity receives network management traffic. Possible values for this object are presently found in the Transport Mappings for SNMPv2 document (RFC 1906 [RFC1906])." ::= { entLogicalEntry 6 }entLogicalContextEngineID OBJECT-TYPE SYNTAX SnmpEngineIdOrNone MAX-ACCESS read-only STATUS current DESCRIPTION "The authoritative contextEngineID that can be used to send an SNMP message concerning information held by this logical entity, to the address specified by the associated 'entLogicalTAddress/entLogicalTDomain' pair. This object, together with the associated entLogicalContextName object, defines the context associated with a particular logical entity, and allows access to SNMP engines identified by a contextEngineId and contextName pair. If no value has been configured by the agent, a zero-length string is returned, or the agent may choose not to instantiate this object at all." ::= { entLogicalEntry 7 }entLogicalContextName OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The contextName that can be used to send an SNMP message concerning information held by this logical entity, to the address specified by the associated 'entLogicalTAddress/entLogicalTDomain' pair. This object, together with the associated entLogicalContextEngineID object, defines the context associated with a particular logical entity, and allowsMcCloghrie & Bierman Standards Track [Page 28]RFC 2737 Entity MIB (Version 2) December 1999 access to SNMP engines identified by a contextEngineId and contextName pair. If no value has been configured by the agent, a zero-length string is returned, or the agent may choose not to instantiate th
?? 快捷鍵說明
復制代碼
Ctrl + C
搜索代碼
Ctrl + F
全屏模式
F11
切換主題
Ctrl + Shift + D
顯示快捷鍵
?
增大字號
Ctrl + =
減小字號
Ctrl + -