Visible light communications (VLC) is the name given to an optical wireless
communication system that carries information by modulating light in the visible spectrum
(400–700 nm) that is principally used for illumination [1–3]. The communications signal
is encoded on top of the illumination light. Interest in VLC has grown rapidly with the
growth of high power light emitting diodes (LEDs) in the visible spectrum. The
motivation to use the illumination light for communication is to save energy by exploiting
the illumination to carry information and, at the same time, to use technology that is
“green” in comparison to radio frequency (RF) technology, while using the existing
infrastructure of the lighting system.
A light-Emitting diode (LED) is a semiconductor device that emits narrow-spectrum incoherent light when forward-biased.The color of the emitted light depends on the chemical composition of the semiconductor material used, and can benear-ultraviolet, visible or infrared. LEDs are more prevalent today than ever before, replacing traditional incandescent andfluorescent bulbs in many lighting applications. Incandescents use a heated filament, are subject to breakage and burnoutand operate at a luminous efficiency of 2% to 4%. Fluorescents are more efficient, at 7% to 12%, but require highdrive voltage and contain mercury, a toxic substance that may be eventually banned in certain countries. LEDs, however,produce light directly through electroluminescence, operate at low voltage and can deliver over 20% luminous efficiency.
This application report discusses the design of non-invasive optical plethysmographyalso called as pulsoximeter using the MSP430FG437 Microcontroller (MCU). Thepulsoximeter consists of a peripheral probe combined with the MCU displaying theoxygen saturation and pulse rate on a LCD glass. The same sensor is used for bothheart-rate detection and pulsoximetering in this application. The probe is placed on aperipheral point of the body such as a finger tip, ear lobe or the nose. The probeincludes two light emitting diodes (LEDs), one in the visible red spectrum (660nm) andthe other in the infrared spectrum (940nm). The percentage of oxygen in the body isworked by measuring the intensity from each frequency of light after it transmitsthrough the body and then calculating the ratio between these two intensities.
摘要:本水位監測報警器使用5V低壓直流電源(也可以用3節5號電池代替)就可以對5~15厘米的水位進行監測,用LED顯示和數碼管顯示水位,并可以對不再此范圍內的水位發出報警。主要采用CD4066、74LS86、74LS32、CD4511芯片,再加上數碼管、蜂鳴器、發光二極管、電阻這些器件組成一個簡單而靈敏的監測報警電路,操作簡單,接通電源即可工作。因為大部分電路采用數字電路,所以本水位監測報警器還具有耗能低、準確性高的特點。關鍵字:譯碼電路 報警電路 監測電路
Abstract: The water level alarm monitoring the use of 5 V low-voltage DC power (can also use three batteries replaced on the 5th) will be able to 5 to 15 centimeters of water level monitoring, with LED display and digital display of water level, and this can no longer Within the scope of a water level alarm. Mainly CD4066, 74LS86, 74LS32, CD4511 chips, coupled with digital control, buzzer, light-Emitting diode, the resistance of these devices composed of a simple and sensitive monitoring alarm circuits. Because the majority of circuits using digital circuitry, so the water level monitored alarm system also has low energy consumption, high accuracy of the characteristics.
Keyword: Decoding circuit alarm circuit monitoring circuit
This application report discusses the design of non-invasive optical plethysmography
also called as pulsoximeter using the MSP430FG437 Microcontroller (MCU). The
pulsoximeter consists of a peripheral probe combined with the MCU displaying the
oxygen saturation and pulse rate on a LCD glass. The same sensor is used for both
heart-rate detection and pulsoximetering in this application. The probe is placed on a
peripheral point of the body such as a finger tip, ear lobe or the nose. The probe
includes two light emitting diodes (LEDs), one in the visible red spectrum (660nm) and
the other in the infrared spectrum (940nm). The percentage of oxygen in the body is
worked by measuring the intensity from each frequency of light after it transmits
through the body and then calculating the ratio between these two intensities.