  • 6位數自動定位控制計數器(72*72mm)

    特點 顯示值范圍-199999至999999位數 最高輸入頻率 5KHz 90度相位差加減算具有提高解析度4倍功能 輸入脈波具有預設刻度功能 定位基準值可任意設定 比較磁滯值可任意設定 數位化指撥設定操作簡易 3組繼電器輸出功能 2:主要規格 脈波輸入型式: Jump-pin selectable current sourcing(NPN) or current sinking (PNP) 脈波觸發電位: HI bias (CMOS) (VIH=7.5V, VIL=5.5V) LO bias (TTL) (VIH=3.7V, VIL=2.0V) 最高輸入頻率: <5KHz 定位置范圍: -199999 to 999999 second adjustabl 比較磁滯范圍: 0 to 9999 adjustable 繼電器容量: AC 250V-5A, DC 30V-7A 顯示值范圍: -199999 to 999999 顯示幕: Red high efficiency LEDs high 9.2mm (.36") 參數設定方式: Touch switches 感應器電源: 12VDC +/-3%(<60mA) 記憶方式: Non-volatile E2PROM memory 絕緣耐壓能力: 2KVac/1 min. (input/output/power) 1600Vdc (input/output) 使用環境條件: 0-50℃(20 to 90% RH non-condensed) 存放環境條件: 0-70℃(20 to 90% RH non-condensed) CE認證: EN 55022:1998/A1:2000 Class A EN 61000-3-2:2000 EN 61000-3-3:1995/A1:2001 EN 55024:1998/A1:2001

    標簽: 72 mm 自動定位 控制

    上傳時間: 2014-12-03

    上傳用戶:xjz632

  • 微電腦型交流電流異常警報電表

    特點 精確度0.25%滿刻度 ±1位數 輸入配線系統可任意選擇 CT比可任意設定 具有異常電流值與異常次數記錄保留功能 電流過高或過低檢測可任意設定 報警繼電器復歸方式可任意設定 尺寸小,穩定性高 2.主要規格 輔助電源: AC110V&220V ±20%(50 or 60Hz) AC220V&440V ±20%(50 or 60Hz)(optional) 精確度: 0.25% F.S. ±1 digit 輸入負載: <0.2VA (Current) 最大過載能力 : Current related input: 2 x rated continuous 10 x rated 30 sec. 25 x rated 3sec. 50 x rated 1 sec. 輸入電流范圍: AC0-5A (10-1000Hz) CT ratio : 1-2000 adjustable 啟動延遲動作時間: 0-99.9 second adjustable 繼電器延遲動作時間: 0-99.9 second adjustable 繼電器復歸方式: Manual (N) / latch(L) can be modified 繼電器磁滯范圍: 0-999 digit adjustable 繼電器動作方向: HI /LO/GO/HL can be modified 繼電器容量: AC 250V-5A, DC 30V-7A 過載顯示: "doFL" 溫度系數: 50ppm/℃ (0-50℃) 顯示幕: Red high efficiency LEDs high 14.22mm(.56")(PV) Red high efficiency LEDs high 14.22mm(.276")(NO) 參數設定方式: Touch switches 記憶型式 : Non-volatile E2PROM memory 絕緣耐壓能力: 2KVac/1 min. (input/output/power) 1600Vdc(input/output 使用環境條件 : 0-50℃(20 to 90% RH non-condensed) 存放環境條件: 0-70℃(20 to 90% RH non-condensed) CE認證: EN 55022:1998/A1:2000 Class A EN 61000-3-2:2000 EN 61000-3-3:1995/A1:2001 EN 55024:1998/A1:2001

    標簽: 微電腦 交流電流 警報電表

    上傳時間: 2013-10-14

    上傳用戶:wanghui2438

  • 微電腦型盤面式異常警報電表

    特點 精確度0.1%滿刻度 ±1位數 可量測 交直流電流/交直流電壓/電位計/傳送器/Pt-100/荷重元/電阻 等信號 顯示范圍-1999-9999可任意規劃 具有異常值與異常次數記錄保留功能 異常信號過高或過低或范圍內或范圍外檢測可任意設定 報警繼電器復歸方式可任意設定 尺寸小,穩定性高 2.主要規格 精確度: 0.1% F.S. ±1 digit 0.2% F.S. ±1 digit(AC) 取樣時間: 16 cycles/sec. 顯示值范圍: -1999 - +9999 digit adjustable 啟動延遲動作時間: 0-99.9 second adjustable 繼電器延遲動作時間: 0-99.9 second adjustable 繼電器復歸方式: Manual (N) / latch(L) can be modified 繼電器動作方向: HI /LO/GO/HL can be modified 繼電器容量: AC 250V-5A, DC 30V-7A 過載顯示: "doFL" 溫度系數: 50ppm/℃ (0-50℃) 顯示幕: Red high efficiency LEDs high 14.22mm(.56")(PV) Red high efficiency LEDs high 7.0mm(.276")(NO) 參數設定方式: Touch switches 記憶型式 : Non-volatile E2PROM memory 絕緣耐壓能力: 2KVac/1 min. (input/output/power) 1600Vdc(input/output 使用環境條件 : 0-50℃(20 to 90% RH non-condensed) 存放環境條件: 0-70℃(20 to 90% RH non-condensed) CE認證: EN 55022:1998/A1:2000 Class A EN 61000-3-2:2000 EN 61000-3-3:1995/A1:2001 EN 55024:1998/A1:2001

    標簽: 微電腦 警報電表

    上傳時間: 2013-11-02

    上傳用戶:fandeshun

  • 比較PSoC與MCU在數位電視設計中的應用

    本文將探討微控制器與 PSoC (可編程系統單晶片)在數位電視應用上的設計挑戰,並比較微控制器和 PSoC 架構在處理這些挑戰時的不同處,以有效地建置執行。

    標簽: PSoC MCU 比較 數位電視

    上傳時間: 2013-11-22

    上傳用戶:gengxiaochao

  • 差分電路中單端及混合模式S-參數的使用

    Single-Ended and Differential S-Parameters Differential circuits have been important incommunication systems for many years. In the past,differential communication circuits operated at lowfrequencies, where they could be designed andanalyzed using lumped-element models andtechniques. With the frequency of operationincreasing beyond 1GHz, and above 1Gbps fordigital communications, this lumped-elementapproach is no longer valid, because the physicalsize of the circuit approaches the size of awavelength.Distributed models and analysis techniques are nowused instead of lumped-element techniques.Scattering parameters, or S-parameters, have beendeveloped for this purpose [1]. These S-parametersare defined for single-ended networks. S-parameterscan be used to describe differential networks, but astrict definition was not developed until Bockelmanand others addressed this issue [2]. Bockelman’swork also included a study on how to adapt single-ended S-parameters for use with differential circuits[2]. This adaptation, called “mixed-mode S-parameters,” addresses differential and common-mode operation, as well as the conversion betweenthe two modes of operation.This application note will explain the use of single-ended and mixed-mode S-parameters, and the basicconcepts of microwave measurement calibration.

    標簽: 差分電路 單端 模式

    上傳時間: 2014-03-25

    上傳用戶:yyyyyyyyyy

  • 穩壓電源設計與技能實訓教程_孫余凱

    本書以普及開關穩壓電源基礎知識、指導設計與檢修穩壓電源電路為主線,詳細講解了線性穩壓電源、PWM開關穩壓電源、諧振式開關穩壓電源等的設計與維修。先以比較簡單的線性穩壓電源為切入點,逐步深入,然后再擴展到PwM開關穩壓電源和諧振式開關穩壓電源,詳細講解各種穩壓電源的原理、特點,以及設計時各種單元電路元器件的選擇方法,最后講解開關電源故障的檢修方法。

    標簽: 穩壓電源設計 技能 教程

    上傳時間: 2013-11-18

    上傳用戶:妄想演繹師

  • 流行單片機實用子程序及應用實例_楊振江

    本書從應用角度出發,精選了在我國最流行的MCS-51、PIC和MCS-96三種單片機的實用子程序和典型器件應用實例20多類100余種。內容包括單片機的基本運算、排序、數碼轉換、數字濾波、軟件抗干擾、串行通信、中斷處理、器件接口等實用程序。書中所涉及的內容大部分都經過上機驗證,具有很強的實用性。有些例子直接來自于科學研究和生產實踐, 有些例子稍加修改就可解決工作中的實際問題。

    標簽: 單片機實用 程序 應用實例

    上傳時間: 2013-11-07

    上傳用戶:xdqm

  • PCB阻抗匹配計算工具(附教程)

    附件是一款PCB阻抗匹配計算工具,點擊CITS25.exe直接打開使用,無需安裝。附件還帶有PCB連板的一些計算方法,連板的排法和PCB聯板的設計驗驗。 PCB設計的經驗建議:       1.一般連板長寬比率為1:1~2.5:1,同時注意For FuJi Machine:a.最大進板尺寸為:450*350mm,       2.針對有金手指的部分,板邊處需作掏空處理,建議不作為連板的部位.     3.連板方向以同一方向為優先,考量對稱防呆,特殊情況另作處理.     4.連板掏空長度超過板長度的1/2時,需加補強邊.       5.陰陽板的設計需作特殊考量.       6.工藝邊需根據實際需要作設計調整,軌道邊一般不少於6mm,實際中需考量板邊零件的排布,軌道設備正常卡壓距離為不少於3mm,及符合實際要求下的連板經濟性.       7.FIDUCIAL MARK或稱光學定位點,一般設計在對角處,為2個或4個,同時MARK點面需平整,無氧化,脫落現象;定位孔設計在板邊,為對稱設計,一般為4個,直徑為3mm,公差為±0.01inch.       8.V-cut深度需根據連板大小及基板板厚考量,角度建議為不少於45°.       9.連板設計的同時,需基於基板的分板方式考量<人工(治具)還是使用分板設備>.  10.使用針孔(郵票孔)聯接:需請考慮斷裂后的毛刺,及是否影響COB工序的Bonding機上的夾具穩定工作,還應考慮是否有無影響插件過軌道,及是否影響裝配組裝. 

    標簽: PCB 阻抗匹配 計算工具 教程

    上傳時間: 2014-12-31

    上傳用戶:sunshine1402

  • PCB阻抗匹配計算工具(附教程)

    附件是一款PCB阻抗匹配計算工具,點擊CITS25.exe直接打開使用,無需安裝。附件還帶有PCB連板的一些計算方法,連板的排法和PCB聯板的設計驗驗。 PCB設計的經驗建議:       1.一般連板長寬比率為1:1~2.5:1,同時注意For FuJi Machine:a.最大進板尺寸為:450*350mm,       2.針對有金手指的部分,板邊處需作掏空處理,建議不作為連板的部位.     3.連板方向以同一方向為優先,考量對稱防呆,特殊情況另作處理.     4.連板掏空長度超過板長度的1/2時,需加補強邊.       5.陰陽板的設計需作特殊考量.       6.工藝邊需根據實際需要作設計調整,軌道邊一般不少於6mm,實際中需考量板邊零件的排布,軌道設備正常卡壓距離為不少於3mm,及符合實際要求下的連板經濟性.       7.FIDUCIAL MARK或稱光學定位點,一般設計在對角處,為2個或4個,同時MARK點面需平整,無氧化,脫落現象;定位孔設計在板邊,為對稱設計,一般為4個,直徑為3mm,公差為±0.01inch.       8.V-cut深度需根據連板大小及基板板厚考量,角度建議為不少於45°.       9.連板設計的同時,需基於基板的分板方式考量<人工(治具)還是使用分板設備>.  10.使用針孔(郵票孔)聯接:需請考慮斷裂后的毛刺,及是否影響COB工序的Bonding機上的夾具穩定工作,還應考慮是否有無影響插件過軌道,及是否影響裝配組裝. 

    標簽: PCB 阻抗匹配 計算工具 教程

    上傳時間: 2013-10-15

    上傳用戶:3294322651

  • PADS出Excel BOM強勢升級

      網上瘋傳的Excel BOM經典腳本,相信諸位PADS用戶再熟悉不過了吧!     但是它還有缺點:   1.元件封裝不能轉換。(元件位號為R/C/L的0402/063/0805/1206封裝自動轉換統一的對應封裝,以方便統計。)   2.元件參數轉換。(電阻的轉換0R時由0mR修正為0R,KR/MR修正為K/M。)   3.不能按元件的SMD屬性來分類統計。   4.有些公司在制作PADS庫元件時,已經為元件建立了Part ID。導出BOM時需要元件的Part ID屬性。   5.不能導出元件坐標。(本人改進導出元件幾何中心坐標,以便貼片生產之用。)   6.不能導出跳線。   7.不能支持WPS。   8.不能自定義導出元件的Part ID屬性。   9.不能自定義位號之間連接符號。   10.導出BOM特殊字符亂碼,比如常見的±/µ/Ω等。(PADS9.5在中文狀態下導出BOM就不會亂碼,     暫時還沒有更好的解決辦法,不過可以在Excel中替換解決。) 11.加載與運行腳本步驟繁冗;運行速度比較慢。(本人改進的代碼速度絕對不會比之前的慢。)