Abstract: This tutorial discusses proper printed-circuit board (PCB) grounding for mixed-signal designs. Formost applications a simple method without cuts in the ground plane allows for successful PCB layouts withthis kind of IC. We begin this document with the basics: where the current flows. Later, we describe how toplace components and route signal traces to minimize problems with crosstalk. Finally, we move on toconsider power supply-currents and end by discussing how to extend what we have learned to circuits withmultiple mixed-signal ICs.
上傳時間: 2013-11-04
上傳用戶:pol123
Portable, battery-powered operation of electronic apparatushas become increasingly desirable. Medical, remotedata acquisition, power monitoring and other applicationsare good candidates for battery operation. In some circumstances,due to space, power or reliability considerations,it is preferable to operate the circuitry from a single 1.5Vcell. Unfortunately, a 1.5V supply eliminates almost alllinear ICs as design candidates. In fact, the LM10 opamp-reference and the LT®1017/LT1018 comparators arethe only IC gain blocks fully specifi ed for 1.5V operation.Further complications are presented by the 600mV dropof silicon transistors and diodes. This limitation consumesa substantial portion of available supply range, makingcircuit design diffi cult. Additionally, any circuit designedfor 1.5V operation must function at end-of-life batteryvoltage, typically 1.3V. (See Box Section, “Componentsfor 1.5V Operation.”)
標簽: Circuitry Operation Single 1017
上傳時間: 2013-12-20
上傳用戶:Wwill
Abstract: Electrolytic capacitors are notorious for short lifetimes in high-temperature applications such asLED light bulbs. The careful selection of these devices with proper interpretation of their specifications isessential to ensure that they do not compromise the life of the end product. This application notediscusses this problem with electrolytic capacitors in LED light bulbs and provides an analysis that showshow it is possible to use electrolytics in such products.
上傳時間: 2013-11-17
上傳用戶:asdfasdfd
Abstract: Investment in smart meters and smart grid end equipment continues to grow worldwide as countriestry to make their electric delivery systems more efficient. However, as critical as the electric deliveryinfrastructure is, it is normally not secured and thus subject to attack. This article describes the concept oflife-cycle security—the idea that embedded equipment in the smart grid must have security designed into theentire life of the product, even back to the contract manufacturer. We also talk about how life-cycle securityapplies to embedded equipment in the smart grid. Potential threats are discussed, as are potential solutionsto mitigate the risks posed by those threats.
上傳時間: 2014-12-24
上傳用戶:熊少鋒
Abstract: Field-programmable gate arrays (FPGAs) are used in a wide variety of applications and end markets, including digital signalprocessing, medical imaging, and high-performance computing. This application note outlines the issues related to powering FPGAs.It also discusses Maxim's solutions for powering Altera® FPGAs.
上傳時間: 2013-11-02
上傳用戶:zhaoman32
Automotive power systems are unforgiving electronicenvironments. Transients to 90V can occur when thenominal voltage range is 10V to 15V (ISO7637), along withbattery reversal in some cases. It’s fairly straightforwardto build automotive electronics around this system, butincreasingly end users want to operate portable electronics,such as GPS systems or music/video players,and to charge their Li-Ion batteries from the automotivebattery. To do so requires a compact, robust, effi cientand easy-to-design charging system
上傳時間: 2013-11-04
上傳用戶:wfl_yy
Each year Vishay releases thousands of new components that enable our customers to create new and superior end products. We recognize that offering unique component solutions helps improve the performance of next-generation devices, overcome technical barriers, and create new markets.
上傳時間: 2013-12-14
上傳用戶:ming529
The design of battery-powered equipment can often bequite challenging. Since few ICs can operate directly fromthe end-of-life voltage from a 2-cell battery (about 1.8V),most systems require a DC/DCconverter. The systemdesigner often has a limited area in which to place the DC/DC converter; associated inductors and capacitors must be
上傳時間: 2013-11-23
上傳用戶:wys0120
Portable, battery-powered operation of electronic apparatushas become increasingly desirable. Medical, remotedata acquisition, power monitoring and other applicationsare good candidates for batteryoperation. In some circumstances,due to space, power or reliability considerations,it is preferable to operate the circuitry from a single 1.5Vcell. Unfortunately, a 1.5V supply eliminates almost alllinear ICs as design candidates. In fact, the LM10 opamp-reference and the LT®1017/LT1018 comparators arethe only IC gain blocks fully specifi ed for 1.5V operation.Further complications are presented by the 600mV dropof silicon transistors and diodes. This limitation consumesa substantial portion of available supply range, makingcircuit design diffi cult. Additionally, any circuit designedfor 1.5V operation mustfunction at end-of-life batteryvoltage, typically 1.3V. (See Box Section, “Componentsfor 1.5V Operation.”)
標簽: Circuitry Operation Single Cell
上傳時間: 2013-10-30
上傳用戶:hz07104032
為了改變目前電網現場作業管理的變電巡檢、變電檢修試驗、輸電線路巡檢檢修等管理系統各自獨立運行,信息不能共享,功能、效率受限,建設和維護成本高的現狀,提出了采用B/S+C/S構架模式,將各現場作業管理模塊和生產MIS(管理系統)集成為一體的現場作業管理系統的設計方案,做到各子系統和生產MIS軟硬資源共享,做到同一數據唯一入口、一處錄入多處使用。各子系統設備人員等基礎信息來源于生產管理系統,各子系統又是生產管理系統的作業數據、缺陷信息的重要來源。經過研究試用成功和推廣應用,目前該系統已在江西電網220 kV及以上變電站全面應用。 Abstract: In order to improve the status that the substation field inspection system, substation equipments maintenance and testing system, power-line inspection and maintenance system are running independent with each other. They can?蒺t share the resource information which accordingly constrains their functions and efficiency, and their construction and maintenance costs are high. This paper introduces a field standardized work management system based on B/S+C/S mode, integrating all field work management systems based on MIS and share the equipments and employee?蒺s data of MIS,the field work data of the sub systems are the source information of MIS, by which the same single data resouce with one-time input can be utilized in multiple places. After the research and testing, this system is triumphantly using in all 220kV and above substations in Jiangxi grid.
上傳時間: 2013-11-15
上傳用戶:han_zh