目的:自主研制一款超聲手術(shù)刀電源控制系統(tǒng),以減少能量的消耗,維持手術(shù)刀的正常溫度。方法:對(duì)超聲換能器在諧振附近的等效電路建立模型,并設(shè)計(jì)基于數(shù)字信號(hào)處理(DSP)的超聲手術(shù)刀的硬件控制系統(tǒng)。結(jié)果:經(jīng)對(duì)電源控制系統(tǒng)的電路和工作性能測(cè)試,生成的電流和電壓的有效值等參數(shù),能夠及時(shí)調(diào)整電源的頻率,并達(dá)到預(yù)期的功能指標(biāo),使超聲手術(shù)刀工作在諧振狀態(tài)。結(jié)論:以DSP為核心設(shè)計(jì)的超聲手術(shù)刀電源控制系統(tǒng),測(cè)試指標(biāo)均能夠達(dá)到預(yù)期的要求,能夠使系統(tǒng)在諧振狀態(tài)下工作。Objective: To independently develop a power control system of ultrasonic scalpel so as to reduce the energy consumption and maintain the Normal temperature of ultrasonic scalpel. Methods: In this paper, the model of equivalent circuit of ultrasonic transducer nearby syntony was built up, and the hardware control system of ultrasonic scalpel based on digital signal processing(DSP) was designed. Results: Through testing the circuit and work performance of power control system, the series of parameters such as effective value and so on which were produced by this system could adjust frequency of power source in time and attain anticipative functional indicator, and it took the ultrasonic scalpel to work in syntonic situation. Conclusion: The tested indicators of power control system of ultrasonic scalpel based on the kernel design of DSP can attain anticipative requirement, and can take this system to work in syntonic situation.