為解決輸油管道溫度壓力參數實時監測的問題,設計了以C8051F930單片機作為控制核心的超低功耗輸油管道溫度壓力遠程監測系統。現場儀表使用高精度電橋采集數據,通過433 MHz短距離無線通信網絡與遠程終端RTU進行通信,RTU通過GPRS網絡與PC上位機進行遠程數據傳輸,在上位機中實現數據存儲和圖形化界面顯示,從而實現輸油管道溫度壓力參數的實時監測和異常報警。經實驗證明,該系統的12位數據采集精度滿足設計要求,漏碼率小于1%,正常工作時間超過5個月,能實時有效地監測輸油管道的溫度壓力參數,節省大量人工成本,有效預防管道參數異常造成的經濟損失和環境污染。
Abstract:
In order to solve the problems on real-time monitoring of pipeline temperature and pressure parameters, the ultra-low power remote pipeline temperature and pressure monitoring system was designed by using the single chip processor C8051F930 as the control core. The high-precision electric bridge was used in field instruments for data collection, the 433MHz short-range wireless communication network was used to make communication between field instrument and RTU, the GPRS was used by the RTU to transmit data to the PC host computer, and the data was stored and displayed in the PC host computer, so the real-time monitoring and exception alerts of pipeline temperature and pressure parameters were achieved. The experiment proves that the system of which error rate is less than 1% over five months working with the 12-bit data acquisition accuracy can effectively monitor the pipeline temperature and pressure parameters in real time, it saves a lot of labor costs and effectively prevents environmental pollution and economic losses caused by abnormal channel parameters.
Abstract: This application note explains the hardware of different types of 1-Wire® interfaces and software examples adapted to this hardware with a focus on serial ports. Depending on the types of iButtons required for a project and the type of computer to be used, the most economical interface is easily found. The hardware examples shown are basically two different types: 5V general interface and 12V RS-232 interface. Within the 5V group a common printed circuit board could be used for all circuits described. The variations can be achieved by different populations of components. The same principal is used for the 12V RS-232 interface. The population determines if it is a Read all or a Read/Write all type of interface.
There are other possible circuit implementations to create a 1-Wire interface. The circuits described in this application note cover many different configurations. For a custom application, one of the described options can be adapted to meet individual needs.
The standard that governs the design of avioniccomponents and systems, DO-254, is one of the mostpoorly understood but widely applicable standardsin the avionic industry. While information on thegeneral aspects of the standard is easy to obtain, thedetails of exactly how to implement the standard aresketchy. And once an entity develops a process thatachieves compliance, the details of how compliancewas achieved become part of the intellectualproperty of that entity. This white paper focuses onthe details of developing a DO-254 compliantprocess for the design of FPGAs.
According to CIBC World Markets, Equity Research, theFlat Panel Display (FPD) industry has achieved sufficientcritical mass for its growth to explode. Thus, it can nowattract the right blend of capital investments and R&Dresources to drive technical innovation toward continuousimprovement in view quality, manufacturing efficiency,and system integration. These in turn are sustainingconsumer interest, penetration, revenue growth, and thepotential for increasing long-term profitability for industryparticipants. CIBC believes that three essential conditionsare now converging to drive the market forward
Abstract: High-performance base-station (BTS) receivers must meet half-IF spurious requirements, whichcan be achieved by using the proper RF mixer. To help engineers, this application note illustrates the
同步技術是跳頻通信系統的關鍵技術之一,尤其是在快速跳頻通信系統中,常規跳頻通信通過同步字頭攜帶相關碼的方法來實現同步,但對于快跳頻來說,由于是一跳或者多跳傳輸一個調制符號,難以攜帶相關碼。對此引入雙跳頻圖案方法,提出了一種適用于快速跳頻通信系統的同步方案。采用短碼攜帶同步信息,克服了快速跳頻難以攜帶相關碼的困難。分析了同步性能,仿真結果表明該方案同步時間短、虛警概率低、捕獲概率高,同步性能可靠。
Abstract:
Synchronization is one of the key techniques to frequency-hopping communication system, especially in the fast frequency hopping communication system. In conventional frequency hopping communication systems, synchronization can be achieved by synchronization-head which can be used to carry the synchronization information, but for the fast frequency hopping, Because modulation symbol is transmitted by per hop or multi-hop, it is difficult to carry the correlation code. For the limitation of fast frequency hopping in carrying correlation code, a fast frequency-hopping synchronization scheme with two hopping patterns is proposed. The synchronization information is carried by short code, which overcomes the difficulty of correlation code transmission in fast frequency-hopping. The performance of the scheme is analyzed, and simulation results show that the scheme has the advantages of shorter synchronization time, lower probability of false alarm, higher probability of capture and more reliable of synchronization.
The standard that governs the design of avioniccomponents and systems, DO-254, is one of the mostpoorly understood but widely applicable standardsin the avionic industry. While information on thegeneral aspects of the standard is easy to obtain, thedetails of exactly how to implement the standard aresketchy. And once an entity develops a process thatachieves compliance, the details of how compliancewas achieved become part of the intellectualproperty of that entity. This white paper focuses onthe details of developing a DO-254 compliantprocess for the design of FPGAs.
According to CIBC World Markets, Equity Research, theFlat Panel Display (FPD) industry has achieved sufficientcritical mass for its growth to explode. Thus, it can nowattract the right blend of capital investments and R&Dresources to drive technical innovation toward continuousimprovement in view quality, manufacturing efficiency,and system integration. These in turn are sustainingconsumer interest, penetration, revenue growth, and thepotential for increasing long-term profitability for industryparticipants. CIBC believes that three essential conditionsare now converging to drive the market forward
This paper addresses the issues relating to the
enforcement of robust stability when implementing the Adaptive
Inverse Control (AIC) scheme. In this scheme, an adaptive
FIR filter is added to a closed-loop system in order to
reduce the output error caused by external disturbances,
enhancing the performance achieved by linear time-invariant
controllers alone.
Linux in a Nutshell, 5th Edition
By Stephen Figgins, Robert Love, Arnold Robbins, Ellen Siever, Aaron Weber
... ... ... ... ... ... ... .....
Publisher: O Reilly
Pub Date: July 2005
ISBN: 0-596-00930-5
Pages: 944
Over the last few years, Linux has grown both as an operating system and a tool for personal and business use. Simultaneously becoming more user friendly and more powerful as a back-end system, Linux has achieved new plateaus: the newer filesystems have solidified, new commands and tools have appeared and become standard, and the desktop--including new desktop environments--have proved to be viable, stable, and readily accessible to even those who don t consider themselves computer gurus.