The LTC®4155 and LTC4156 are dual multiplexed-inputbattery chargers with PowerPath™ control, featuring I2Cprogrammability and USB On-The-Go for systems suchas tablet PCs and other high power density applications.The LTC4155’s float voltage (VFLOAT) range is optimizedfor Li-Ion batteries, while the LTC4156 is optimized forlithium iron phosphate (LiFePO4)batteries, supportingsystem loads to 4A with up to 3.5A of battery chargecurrent. I2C controls a broad range of functions and USBOn-The-Go functionality is controlled directly from theUSB connector ID pin.
上傳時間: 2013-10-09
上傳用戶:hanhanj
A frequent requirement in systems involves drivinganalog signals into non-linear or reactive loads. Cables,transformers, actuators, motors and sample-hold circuitsare examples where the ability to drive diffi cult loads isrequired. Although several power buffer amplifi ers areavailable, none have been optimized for driving diffi cultloads.
上傳時間: 2014-12-24
上傳用戶:1109003457
Abstract: As electronic systems take over many of the mechanical functions in a car—ranging from engine timing to steering andbraking—there is a growing concern about fault tolerance. There should not be a single point of failure that would prevent a car fromat least "limping" off the road or making it to the nearest service station. Redundant systems, watchdog timers, and other controlcircuits are used to reroute signals and perform other functions that ensure that a vehicle can safely make it off the road when afailure occurs.
上傳時間: 2013-11-10
上傳用戶:diets
Avalanche photodiodes (APDs) are widely utilized in laserbased fiberoptic systems to convert optical data intoelectrical form. The APD is usually packaged with a signalconditioning amplifier in a small module. An APD receivermodule and attendant circuitry appears in Figure 1. TheAPD module (figure right) contains the APD and a transimpedance(e.g., current-to-voltage) amplifier. An opticalport permits interfacing fiberoptic cable to the APD’sphotosensitive portion. The module’s compact constructionfacilitates a direct, low loss connection between theAPD and the amplifier, necessary because of the extremelyhigh speed data rates involved
上傳時間: 2013-10-25
上傳用戶:brain kung
As logic systems get larger and more complex, theirsupply current requirements continue to rise. Systemsrequiring 100A are fairly common. A high current powersupply to meet such requirements usually requires parallelingseveral power regulators to alleviate the thermalstress on the individual power components. A powersupply designer is left with the choice of how to drive theseparalleled regulators: brute-force single-phase or smartPolyPhaseTM.
上傳時間: 2013-10-08
上傳用戶:zhqzal1014
Notebook and palmtop systems need a multiplicity ofregulated voltages developed from a single battery. Smallsize, light weight, and high efficiency are mandatory forcompetitive solutions in this area. Small increases inefficiency extend battery life, making the final productmuch more usable with no increase in weight. Additionally,high efficiency minimizes the heat sinks needed onthe power regulating components, further reducing systemweight and size.
上傳時間: 2013-11-11
上傳用戶:大三三
The design of battery-powered equipment can often bequite challenging. Since few ICs can operate directly fromthe end-of-life voltage from a 2-cell battery (about 1.8V),most systems require a DC/DCconverter. The systemdesigner often has a limited area in which to place the DC/DC converter; associated inductors and capacitors must be
上傳時間: 2013-11-23
上傳用戶:wys0120
In predominantly digital systems it is often necessaryto include linear circuit functions. Traditionally, separatepower supplies have been used to run the linear components(see Box, “Linear Power Supplies—Past, Present,and Future”).
標簽: Designing Operation Circuits Linear
上傳時間: 2013-11-04
上傳用戶:sdq_123
為了改變目前電網現場作業管理的變電巡檢、變電檢修試驗、輸電線路巡檢檢修等管理系統各自獨立運行,信息不能共享,功能、效率受限,建設和維護成本高的現狀,提出了采用B/S+C/S構架模式,將各現場作業管理模塊和生產MIS(管理系統)集成為一體的現場作業管理系統的設計方案,做到各子系統和生產MIS軟硬資源共享,做到同一數據唯一入口、一處錄入多處使用。各子系統設備人員等基礎信息來源于生產管理系統,各子系統又是生產管理系統的作業數據、缺陷信息的重要來源。經過研究試用成功和推廣應用,目前該系統已在江西電網220 kV及以上變電站全面應用。 Abstract: In order to improve the status that the substation field inspection system, substation equipments maintenance and testing system, power-line inspection and maintenance system are running independent with each other. They can?蒺t share the resource information which accordingly constrains their functions and efficiency, and their construction and maintenance costs are high. This paper introduces a field standardized work management system based on B/S+C/S mode, integrating all field work management systems based on MIS and share the equipments and employee?蒺s data of MIS,the field work data of the sub systems are the source information of MIS, by which the same single data resouce with one-time input can be utilized in multiple places. After the research and testing, this system is triumphantly using in all 220kV and above substations in Jiangxi grid.
上傳時間: 2013-11-15
上傳用戶:han_zh
Sensing and/or controlling current flow is a fundamental requirement in many electronics systems, and the tech-niques to do so are as diverse as the applications them-selves. This Application Note compiles solutions to cur-rent sensing problems and organizes the solutions by general application type. These circuits have been culled from a variety of Linear Technology documents
標簽: 電流檢測電路
上傳時間: 2013-10-22
上傳用戶:moshushi0009