微弱信號檢測裝置
四川理工學院 劉鵬飛、梁天德、曾學明
摘要:
本設(shè)計以TI的Launch Pad為核心板,采用鎖相放大技術(shù)設(shè)計并制作了一套微弱信號檢測裝置,用以檢測在強噪聲背景下已知頻率微弱正弦波信號的幅度值,并在液晶屏上數(shù)字顯示出所測信號相應(yīng)的幅度值。實驗結(jié)果顯示其抗干擾能力強,測量精度高。
關(guān)鍵詞:強噪聲;微弱信號;鎖相放大;Launch Pad
Abstract:
This design is based on the Launch Pad of TI core board, using a lock-in amplifier technique designed and produced a weak signal detection device, to measure the known frequency sine wave signal amplitude values of the weak in the high noise background, and shows the measured signal amplitude of the corresponding value in the liquid crystal screen. Test results showed that it has high accuracy and strong anti-jamming capability.
Keywords: weak signal detection; lock-in-amplifier; Launch Pad
1、引言
隨著現(xiàn)代科學技術(shù)的發(fā)展,在科研與生產(chǎn)過程中人們越來越需要從復雜高強度的噪聲中檢測出有用的微弱信號,因此對微弱信號的檢測成為當前科研的熱點。微弱信號并不意味著信號幅度小,而是指被噪聲淹沒的信號,“微弱”也僅是相對于噪聲而言的。只有在有效抑制噪聲的條件下有選擇的放大微弱信號的幅度,才能提取出有用信號。微弱信號檢測技術(shù)的應(yīng)用相當廣泛,在生物醫(yī)學、光學、電學、材料科學等相關(guān)領(lǐng)域顯得愈發(fā)重要。
2、方案論證
針對微弱信號的檢測的方法有很多,比如濾波法、取樣積分器、鎖相放大器等。下面就針對這幾種方法做一簡要說明。
方案一:濾波法。
在大部分的檢測儀器中都要用到濾波方法對模擬信號進行一定的處理,例如隔離直流分量,改善信號波形,防止離散化時的波形混疊,克服噪聲的不利影響,提高信噪比等。常用的噪聲濾波器有:帶通、帶阻、高通、低通等。但是濾波方法檢測信號不能用于信號頻譜與噪聲頻譜重疊的情況,有其局限性。雖然可以對濾波器的通頻帶進行調(diào)節(jié),但其噪聲抑制能力有限,同時其準確性與穩(wěn)定性將大打折扣。