ABSTRACTThe flyback power stage is a popular choice for single and multiple output dc-to-dc converters at powerlevels of 150 Watts or less. Without the output inductor required in buck derived topologies, such as theforward or push-pull converter, the component count and cost are reduced. This application note will reviewthe design procedure for the power stage and control electronics of a flyback converter. In these isolatedconverters, the error signal from the secondary still needs to cross the isolation boundary to achieveregulation. By using the UC3965 Precision Reference with Low Offset Error Amplifier on the secondaryside to drive an optocoupler and the UCC3809 Economy Primary Side Controller on the primary side, asimple and low cost 50 Watt isolated power supply is realized.
MAX30102芯片心率血氧傳感器模塊傳感器模塊軟硬件設計資料包括STM32測試源碼AD設計原理圖及心率及血氧參考設計資料:參考代碼及實驗數據工程文件及庫心率及血氧參考設計資料芯片數據手冊1771.pdf2ES Teck PEMS White Paper.pdf31930_accessories.pdf5273c08fe2b6b_1_4264142A_EN_p.pdfAvant 2120 Brochure.pdfcelyon-1057-daeg.pdfDr. Bob case study for dental.pdfenvitec.pdfgclarke-2015-MASc-thesis.pdfiadt02i4p261.pdfIHE_PCD_Suppl_POI.pdfijcsit2014050679.pdfIMECS2009_pp1537-1540.pdfLuksSwensonPulseOximetryatHighAltitude.pdfMI_CCHD_Screener_Tips_Flier_3-21-13_422078_7.pdfMoon.pdfnotes6.pdfpansw_spo2_sensor.pdfPK_EN_MAsimo2008Product Catalog.pdfpm-60a-spo2-report-4.pdfpulse-oximetry-at-home.pdfpulse-oximetry.pdfpulse.pdfPulseOxFinal_low.pdfpulse_ox.pdfpxc3976461.pdfReusable SpO2 Sensors.pdfSP02-cross-reference-sensor.pdfsprt533.pdfsszb140.pdfview.pdf
基于TMS320F28335的超聲波流量計硬件原理圖+軟件源碼本文以TMS320F28335 處理器為核心,設計一種用于管道流量測量的超聲波流量計。系統硬件由核心板,超聲波發射和接收電路,切換電路,超聲換能器,基于ADS805 的高速信號采集電路,人機交互以及電源等模塊構成。采用時差法進行管道流量測量,時差測量采用SCOT 加權的廣義互相關時延估計算法。本論文設計的超聲波流量計具有測量速度快、準確性好、成本低等優點。關鍵字:C2000,超聲波,流量,廣義互相關算法AbstractA kind of ultrasonic flowmeter using for the pipe flow measurement is designed based onTMS320F28335 in this paper. The system hardware consists of the following parts: the core board,ultrasonic signal transmitter and receiver circuits, switch circuit, ultrasonic transducer, signalacquisition circuit based on ADS805, human-computer interaction module and power supplymodule, etc. The system use the method of time difference for pipeline flow measurement and thetime difference is calculated by the time-delay algorithm of SCOT weighted generalizedcross-correlation. The ultrasonic flowmeter has the features of high testing speed, high precisionand low cost, etc.Keywords: C2000,Ultrasonic, Flow, Generalized Cross-Correlation Algorithm
le flows through MOS channel while Ih flows across PNP transistor Ih= a/(1-a) le, IE-le+lh=1/(1-a)' le Since IGBT has a long base PNP, a is mainly determined by ar si0 2ar= 1/cosh(1/La), La: ambipolar diff length a-0.5 (typical value)p MOSFET channel current (saturation), le=U"Cox"W(2"Lch)"(Vc-Vth)le Thus, saturated collector current Ic, sat=1/(1-a)"le=-1/(1-a)"UCox"W/(2Lch)"(Vo-Vth)2Also, transconductance gm, gm= 1/(1-a)"u' Cox W/Lch*(Vo-Vth)Turn-On1. Inversion layer is formed when Vge>Vth2. Apply positive collector bias, +Vce3. Electrons flow from N+ emitter to N-drift layer providing the base current for the PNP transistor4. Since J1 is forward blased, hole carriers are injected from the collector (acts as an emitter).5. Injected hole carriers exceed the doping level of N-drift region (conductivity modulation). Turn-Off1. Remove gate bias (discharge gate)2. Cut off electron current (base current, le, of pnp transistor)