As a programming language, C is rather like Pascal or Fortran.. Values are stored in variables.
Programs are structured by defining and calling functions. Program flow is controlled using loops, if
statements and function calls. Input and output can be directed to the terminal or to files. Related data
can be stored together in arrays or structures.
The Java(tm) Telnet Applet is a fully featured telnet/SSH program that allows users to connect and login to remote hosts via the Internet or an Intranet using only their WWW Browser. It includes not only telnet-compliant connection services.
This application note considers the design of frequency-
selective filters, which modify the frequency content
and phase of input signals according to some specification.
Two classes of frequency-selective digital filters
are considered: infinite impulse response (IIR) and finite
impulse response (FIR) filters. The design process
consists of determining the coefficients of the IIR or FIR
filters, which results in the desired magnitude and
phase response being closely approximated.
This application note considers the design of frequency-
selective filters, which modify the frequency content
and phase of input signals according to some specification.
Two classes of frequency-selective digital filters
are considered: infinite impulse response (IIR) and finite
impulse response (FIR) filters. The design process
consists of determining the coefficients of the IIR or FIR
filters, which results in the desired magnitude and
phase response being closely approximated.
un the configuration script
----------------------------
In the CGIs directory there is a configure.s and a configure.bat file.
Run this file after you ve moved the CGIs directory to it s desired
location. The configure script will create a file nammed apache.conf.
Append this file the the httpd.conf file.
LINUX:
[prompt]$ ./configure.s
[prompt]$ cat apache.conf >> /etc/httpd/conf/httpd.conf
Note: you may need to set the executable flag on the script
chmod 755 configure.s
WINDOWS:
prompt> configure.bat
Copy the contents of apache.conf to httpd.conf
Features a unique program to estimate the power spectral density. The spectrum containing all significant details is calculated from a time series model. Model type as well as model order are determined automatically from the data, using statistical criteria. Robust estimation algorithms and order selection criteria are used to obtain reliable results. Unlike in FFT analysis, where the experimenter has to set the amount of smoothing of the raw FFT, the right level of detail is assessed using the data only.
A large body of computer-aided techniques has been developed in recent years to assist
in the process of modeling, analyzing, and designing communication systems . These
computer-aided techniques fall into two categories: formula-based approaches, where the
computer is used to evaluate complex formulas, and simulation-based approaches, where the
computer is used to simulate the waveforms or signals that flow through the system. The
second approach, which involves “waveform”-level simulation (and often incorporates
analytical techniques), is the subject of this book.
Since performance evaluation and trade off studies are the central issues in the analysis
and design of communication systems, we will focus on the use of simulation for evaluating
the performance of analog and digital communication systems with the emphasis on digitalcommunication systems.
Collection of key-value pairs.
TDictionary represents a generic collection of key-value pairs.
This class provides a mapping from a collection of keys to a collection of values. When you create a TDictionary object, you can specify various combinations of initial capacity, equality operation, and initial content.
You can add a key that is associated with a corresponding value with the Add or AddOrSetValue methods. You can remove entries with Remove or Clear, which removes all key-value pairs. Adding or removing a key-value pair and looking up a key are efficient, close to O(1), because keys are hashed. A key must not be nil (though a value may be nil) and there must be an equality comparison operation for keys.
You can test for the presence or keys and values with the TryGetValue, ContainsKey and ContainsValue methods.
The Items property lists all Count dictionary entries. You can also set and get values by indexing the Items property. Setting the value this way overwrites any existing value.
The class TObjectDictionary inherits from TDictionary and provides an automatic mechanism for freeing objects removed from dictionary entries.
Agilent 34401A Service Guide.pdfIEC Measurement Category II includes electrical devices connected to mains at an outlet on a branch circuit. Such devices include
most small appliances, test equipment, and
other devices that plug into a branch outlet
or socket. The 34401A may be used to make
measurements with the HI and LO inputs
connected to mains in such devices, or to
the branch outlet itself (up to 300 VAC).
However, the 34401A may not be used with
its HI and LO inputs connected to mains in
permanently installed electrical devices
such as the main circuit-breaker panel,
sub-panel disconnect boxes, or permanently
wired motors. Such devices and circuits are
subject to overvoltages that may exceed the
protection limits of the 34401A.
Note: Voltages above 300 VAC may be measured only in circuits that are isolated from
mains. However, transient overvoltages are
also present on circuits that are isolated
from mains. The Agilent 34401A are
designed to safely withstand occasional
transient overvoltages up to 2500 Vpk. Do
not use this equipment to measure circuits
where transient overvoltages could exceed
this level.
Additional Notices
Waste Electrical and
Electronic Equipment (WEEE)
Directive 2002/96/EC
This product complies with the WEEE Directive (2002/96/EC) marking requirement.
The affixed product label (see below) indicates that you must not discard this electrical/electronic product in domestic
household waste.
Product Category: With reference to the
equipment types in the WEEE directive
Annex 1, this product is classified as a
"Monitoring and Control instrumentation"
product.
Do not dispose in domestic household
waste.
To return unwanted products, contact your
local Agilent office, or see
www.agilent.com/environment/product
for more information.
Agilent 34138A Test Lead Set
The Agilent 34401A is compatible with the
Agilent 34138A Test Lead Set described
below.
Test Lead Ratings
Test Leads - 1000V, 15A
Fine Tip Probe Attachments - 300V, 3A
Mini Grabber Attachment - 300V, 3A
SMT Grabber Attachments - 300V, 3A
Operation
The Fine Tip, Mini Grabber, and SMT Grabber attachments plug onto the probe end of
the Test Leads.
Maintenance
If any portion of the Test Lead Set is worn or
damaged, do not use. Replace with a new
Agilent 3413