Many applications require a clock signal to be synchronous, phase-locked, or derived fromanother signal, such as a data signal or another clock. This type of clock circuit is important in
Abstract: Transimpedance amplifiers (TIAs) are widely used to translate the current output of sensors like photodiode-to-voltagesignals, since several circuits and instruments can only accept voltage input. An operational amplifier with a feedback resistor fromoutput to the inverting input is the most straightforward implementation of such a TIA. However, even this simple TIA circuit requirescareful trade-offs among noise gain, offset voltage, bandwidth, and stability. Clearly stability in a TIA is essential for good, reliableperformance. This application note explains the empirical calculations for assessing stability and then shows how to fine-tune theselection of the feedback phase-compensation capacitor.
Linear Technology’s High Frequency Product lineupincludes a variety of RF I/Q modulators. The purpose ofthis application note is to illustrate the circuits requiredto interface these modulators with several popular D/Aconverters. Such circuits typically are required to maximizethe voltage transfer from the DAC to the baseband inputsof the modulator, as well as provide some reconstructionfi ltering.
Control systems are becoming increasingly dependent on digital processing and so require sensors able to provide direct digital inputs. Sensors based on time measurement, having outputs based on a frequency or phase, have an advantage over conventional analogue sensors in that their outputs can be measured directly in digital systems by pulse counting.
This application note describes a Linear Technology "Half-Flash" A/D converter, the LTC1099, being connected to a 256 element line scan photodiode array. This technology adapts itself to handheld (i.e., low power) bar code readers, as well as high resolution automated machine inspection applications..
Highlights the LTC1062 as a lowpass filter in a phase lock loop. Describes how the loop's bandwidth can be increased and the VCO output jitter reduced when the LTC1062 is the loop filter. Compares it with a passive RC loop filter. Also discussed is the use of LTC1062 as simple bandpass and bandstop filter.
Sensors for pressure, load, temperature, acceleration andmany other physical quantities often take the form of aWheatstone bridge. These sensors can be extremely linearand stable over time and temperature. However, mostthings in nature are only linear if you don’t bend them toomuch. In the case of a load cell, Hooke’s law states that thestrain in a material is proportional to the applied stress—as long as the stress is nowhere near the material’s yieldpoint (the “point of no return” where the material ispermanently deformed).
Over the past several years Linear Technology, the magazine, has come of age. From nothing, the publication has come into its own, as has its subscriber list. Many innovative circuits have seen the light of day in the pages of our now hallowed publication.
分析了調幅信號和載波信號之間的相位差與調制信號的極性的對應關系,得出了相敏檢波電路輸出電壓的極性與調制信號的極性有對應關系的結論。為了驗證相敏檢波電路的這一特性,給出3 個電路方案,分別選用理想元件和實際元件,采用Multisim 對其進行仿真實驗,直觀形象地演示了相敏檢波電路的鑒相特性,是傳統的實際操作實驗所不可比擬的。關鍵詞:相敏檢波;鑒相特性;Multisim;電路仿真
Abstract : The corresponding relation between modulation signal polarity and difference phases of amplitudemodulated signal and the carrier signal ,the polarity of phase2sensitive detecting circuit output voltage and the polarity of modulation signal are correspondent . In order to verify this characteristic ,three elect ric circuit s plans are produced ,idea element s and actual element s are selected respectively. Using Multisim to carry on a simulation experiment ,and then demonst rating the phase detecting characteristic of the phase sensitive circuit vividly and directly. Which is t raditional practical experience cannot be com pared.Keywords :phase sensitive detection ;phase2detecting characteristic ;Multisim;circuit simulation
Power conversion by virtue of its basic role produces harmonics due to theslicing of either voltages or currents. To a large extent the pollution in theutility supply and the deterioration of the power quality has been generatedor created by non-linear converters. It is therefore ironic that power convertersshould now be used to clean up the pollution that they helped to create inthe first place.In a utility system, it is desirable to prevent harmonic currents (which resultin EMI and resonance problems) and limit reactive power flows (whichresult in transmission losses).Traditionally, shunt passive filters, comprised of tuned LC elements andcapacitor banks, were used to filter the harmonics and to compensate forreactive current due to non-linear loads. However, in practical applicationsthese methods have many disadvantages.