Occasionally, we are tasked with designing circuitry for aspecific purpose. The request may have customer originsor it may be an in-house requirement. Alternately, a circuitmay be developed because its possibility is simply tooattractive to ignore1. over time, these circuits accumulate,encompassing a wide and useful body of proven capabilities.They also represent substantial effort. These considerationsmake publication an almost obligatory propositionand, as such, a group of circuits is presented here. This isnot the first time we have displayed such wares and, giventhe encouraging reader response, it will not be the last2.Eighteen circuits are included in this latest effort, roughlyarranged in the categories given in this publication’s title.They appear at the next paragraph.
Features: High efficiency, high reliability, low cost AC input range selected by switch 100% full load burn-in test Protections: Short circuit / over load Fixed switching frequency at 25KHz Cooling by free air convection 1 year warranty Dimensions: 199*98*38mm (L*W*H)
Analog Inputs and Outputs in an S7 PLC are represented in the PLC as a 16-bit integer. over
the nominal span of the analog input or output, the value of this integer will range between -
27648 and +27648. However, it is easier to use the analog values if they are scaled to the
same units and ranges as the process being controlled. This applications tip describes
methods for scaling analog values to and from engineering units.
The MAX9257/MAX9258 programmable serializer/deserializer (SerDes) devices transfer both video data and control signals over the same twisted-pair cable. However, control data can only be transmitted during the vertical blank time, which is indicated by the control-channel-enabled output (CCEN) signal. The electronic control unit (ECU) firmware designer needs to know how quickly to respond to the CCEN signal before it times out and how to calculate this duration. This application note describes how to calculate the duration of the CCEN for the MAX9257/MAX9258 SerDes chipset. The calculation is based on STO timeout, clock frequency, and UART bit timing. The CCEN duration is programmable and can be closed if not in use.
Designing Boards with Atmel AT89C51,AT89C52, AT89C1051, and AT89C2051 for Writing Flash at In-Circuit Test.
Recent improvements in chips and testers have made it possible for the tester to begin taking over the role tradi-tionally assigned to the PROM program-mer. Instead of having a PROM pro- grammer write nonvolatile memories before assembling the board, the in-cir- cuit tester writes them during in-circuit testing operations. Many Teradyne Z18- series testers are now in use loading code into nonvolatile memories, micro- controllers and in-circuit programmable logic devices. The purpose of this note is to explain how the Z18 approaches the writing task for Atmel AT89C series IC’s, so that designers of boards using these chips can get the best results.
為解決輸油管道溫度壓力參數實時監測的問題,設計了以C8051F930單片機作為控制核心的超低功耗輸油管道溫度壓力遠程監測系統。現場儀表使用高精度電橋采集數據,通過433 MHz短距離無線通信網絡與遠程終端RTU進行通信,RTU通過GPRS網絡與PC上位機進行遠程數據傳輸,在上位機中實現數據存儲和圖形化界面顯示,從而實現輸油管道溫度壓力參數的實時監測和異常報警。經實驗證明,該系統的12位數據采集精度滿足設計要求,漏碼率小于1%,正常工作時間超過5個月,能實時有效地監測輸油管道的溫度壓力參數,節省大量人工成本,有效預防管道參數異常造成的經濟損失和環境污染。
Abstract:
In order to solve the problems on real-time monitoring of pipeline temperature and pressure parameters, the ultra-low power remote pipeline temperature and pressure monitoring system was designed by using the single chip processor C8051F930 as the control core. The high-precision electric bridge was used in field instruments for data collection, the 433MHz short-range wireless communication network was used to make communication between field instrument and RTU, the GPRS was used by the RTU to transmit data to the PC host computer, and the data was stored and displayed in the PC host computer, so the real-time monitoring and exception alerts of pipeline temperature and pressure parameters were achieved. The experiment proves that the system of which error rate is less than 1% over five months working with the 12-bit data acquisition accuracy can effectively monitor the pipeline temperature and pressure parameters in real time, it saves a lot of labor costs and effectively prevents environmental pollution and economic losses caused by abnormal channel parameters.
針對當前安檢力學試驗機所能完成的試驗種類單一、自動化程度低等問題,提出一種以ATmega128單片機為核心控制器的安檢力學試驗機的設計。詳細闡述了該安檢力學試驗機各個組成部分的設計原理和方案,并且給出了各部分的軟件設計思想和操作流程。經過大量測試試驗表明:設計的安檢力學試驗機可以完成多達十余種的力學安檢試驗,完全符合相關國家標準,并且具有數據采集精度高、傳輸速度快、操作安全簡便等特點,實現了安檢設備的多功能化、數字化和自動化。
Abstract:
Currently, many mechanical security testing machines have only one function. The degree of automation of them is low. To solve those problems, a new kind of mechanical security testing machine, using ATmega128 micro-controller as its core controller, has been advanced. It describes the components of the machine. The principles and the scheme in the designing processes are presented in detail, and the software architecture and the operation processes of each part are given. After having done many testing, we have reached the following conclusions: the mechanical security testing machine presented can do over ten mechanical security tests complying with related national standards. It has high data acquisition accuracy and high transmission speed. The operation of the machine is simple and safe. In general, this machine is a multi-functional, highly automatic, digitalized security testing device.
The SN65LBC170 and SN75LBC170 aremonolithic integrated circuits designed forbidirectional data communication on multipointbus-transmission lines. Potential applicationsinclude serial or parallel data transmission, cabledperipheral buses with twin axial, ribbon, ortwisted-pair cabling. These devices are suitablefor FAST-20 SCSI and can transmit or receivedata pulses as short as 25 ns, with skew lessthan 3 ns.These devices combine three 3-state differentialline drivers and three differential input linereceivers, all of which operate from a single 5-Vpower supply.The driver differential outputs and the receiverdifferential inputs are connected internally to formthree differential input/output (I/O) bus ports thatare designed to offer minimum loading to the buswhenever the driver is disabled or VCC = 0. Theseports feature a wide common-mode voltage rangemaking the device suitable for party-lineapplications over long cable runs.